Lincoln Electric SVM158-A service manual To Work

Models: SVM158-A

1 167
Download 167 pages 56.76 Kb
Page 37
Image 37

C-11

C-11

ACCESSORIES

Return to Master TOC

Return to Master TOC

CONNECTION OF THE LN-10 TO THE V350-PRO USING THE K1505 CONTROL CABLE.

NOTE: AN LN-10 CAN ONLY BE USED WITH A FAC- TORY OR “CE” VERSION OF THE V350-PRO.

1.Remove input power to the V350-PRO.

2.Connect the K1505 control cable from the LN-10 to the Invertec 24/42VAC 14 pin amphenol con- necter on the rear of the V350-PRO.

3.Connect the electrode cable to the output terminal of polarity required by the electrode. Connect the work lead to the other terminal.

4.Set the meter polarity switch on the front of the V350-PRO to coincide with wire feeder polarity used.

5.Set “CONTROL SELECT” to “REMOTE”.

6.Set the “MODE” to the “CV-WIRE” position..

7.Set the “WELD TERMINALS SELECT” to the “REMOTE” position.

8.Set the “ARC CONTROL” to the “0” position and then adjust to suit.

9.Set wire feed speed and voltage at the LN-10. NOTE: The voltage set point displayed on the V350-PRO should be ignored when operating in the remote control mode with the LN-10.

10.See the LN-10 manual for details on accessing the control DIP switch.

11.The control DIP switch inside the LN-10 should be set per the instructions in the LN-10 manual.

Return to Section TOC

Return to Section TOC

Figure C.8 LN-10 V350-PRO

14 PIN

TO LN-10

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

AMPHENOL (24/42VAC)

AT REAR OF MACHINE

+

-

K1505

 

 

TO WORK

ELECTRODE CABLE

TO LN-10

V350-PRO