Lincoln Electric SVM158-A service manual Lower Case Panel

Models: SVM158-A

1 167
Download 167 pages 56.76 Kb
Page 21
Image 21

B-9

B-9

OPERATION

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

LOWER CASE PANEL

The output studs, line switch and remote connector are located on the lower case front.

9.Both terminals are "Twist-Mate"connectors.

The Negative terminal is configured to accept the pass through gas system.

10.The METER POLARITY switch is located above the output connectors. The switch provides a work connection for wire feeder voltmeters. Place the switch in the position of the electrode polarity indi- cated by the decal. The switch does not change the welding polarity.

11.6-pinMS-style connector for remote control.

12.14-pinMS-style connector for wire feeder connec- tion and remote control.

REMOTE CONTROL of the OUTPUT CONTROL and

WELD TERMINALS

The Invertec V350-Pro has auto sensing of remote out- put controls. If after connecting or removing a remote, the Invertec V350-Pro did not configure the way you would like the local or remote control settings can be changed by pushing the OUTPUT CONTROL or WELD TERMINAL button. (A user cannot select between the 6 and 14 pin MS-style connectors.)

CV modes

The remote will default to the 14-pin MS-style con- nector if a remote is connected. If no remote is con- nected to the 14-pin MS-style connector then the remote will default to the 6-pin MS-style connector if a remote is connected to it.

In all of the CV modes, the WELD TERMINAL con- trol will default to REMOTE.

TIG mode

The remote will default to the 6-pin MS-style if a remote control is connected to the 6-pin MS-style and to the 14-pin MS-style connector. If a remote is not connected to the 6-pin MS-style connector then the remote will default to the 14-pin MS-style con- nector if a remote is connected.

If a remote control is connected to any of the MS- style connectors the WELD TERMINAL control will default to REMOTE. If there are not any remote con- trol devices attached the WELD TERMINAL control will default to ON.

CC-Stick modes

The remote will default to only the 6-pin MS-style connector if a remote is connected to it.

The WELD TERMINAL control will default to ON with or without a remote connected.

Types of Remote OUTPUT CONTROL

The Invertec V350-Pro’s Output Control can be con- trolled by either a potentiometer connected between 77 & 75 with the wiper connected to 76 or a 0V to 10V DC supply connected between 76 & 75. (76 needs to be positive)

14-Pin Ms-style connector lead 75 is pin G, lead 76 is pin F and lead 77 is pin E.

6-Pin Ms-style connector lead 75 is pin C, lead 76 is pin B and lead 77 is pin A.

Potentiometer Control

The total resistance should be between 2000 ohms (2K) and 10,000 ohms (10K)

The machine output will be at minimum when lead 76 (wiper) is at the end of the potentiometer that is connected to 75. The machine’s output will increase as the wiper of the potentiometer is moved to the end that is connected to 77. (Note: In TIG mode, moving the lead 76 (wiper) to lead 77 would produce the cur- rent that has been set by the Invertec V350-Pro’s front panel Output Control.)

Remotes of this type offered by Lincoln Electric are the K857, K812 and K870.

Voltage Control

The supply must be an isolated supply. (Not refer- enced to earth ground, any auxiliary power from the Invertec V350-Pro or the welding output) The supply should be capable of supplying at least 20mA.

0 volts supplied to 76 will set the Invertec V350-Pro to minimum output for the mode that has been selected while 10 volts supplied to 76 will set the Invertec V350-Pro to the maximum output for the mode. (Note: In TIG mode, 10 volts supplied to lead 76 would produce the current that has been set by the Invertec V350-Pro’s front panel Output Control.)

Types of Remote WELD TERMINAL Control

The Invertec V350-Pro’s Weld Terminals can be con- trolled from each of the MS-style connectors. The circuit has a nominal OCV of 15VDC and requires a dry contact closure (less than 100 ohms) to activate the output of the Invertec V350-Pro.

14-Pin MS-style connector, the Weld Terminals are controlled from pin C (lead 2) and pin D (lead 4). Pin C is positive.

6-Pin MS-style connector, the Weld Terminals are controlled from pin D (lead 2) and pin E (lead 4). In the 6-pin MS-style connector pin D is positive.