Lincoln Electric SVM158-A service manual Installation

Models: SVM158-A

1 167
Download 167 pages 56.76 Kb
Page 8
Image 8

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

 

A-2

 

 

 

 

 

 

INSTALLATION

 

 

 

 

 

A-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS - INVERTEC V350-PRO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT AC VOLTAGE & DC OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product

Ordering

Input AC

 

Rated DC Output

 

Output

 

 

Weight

 

Dimensions

 

Open

 

 

Name

Information

Voltage

 

Amps/Volt

 

Range

 

with Cord

 

HxWxD

 

Circuit

 

 

 

 

 

 

 

 

/Duty Cycle

(continuous)

 

 

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K1728-5

 

 

 

 

 

 

 

 

 

Construction

 

 

 

 

 

 

 

Construction

200

 

350A / 34V / 60%

 

 

 

 

(81.0 lbs.)

14.8” x 13.3” x

 

 

 

 

 

 

 

 

 

 

 

 

(36.7 kg.)

 

 

 

 

Invertec

K1728-6

208-230/

 

 

 

 

 

 

 

 

 

 

 

27.8”*

 

 

 

 

V350-

 

Factory

380-400/

 

 

 

 

AMPS

 

 

Factory

 

(373 x 338 x

 

 

 

 

PRO

 

 

415-460/

 

 

 

 

5-425

 

(81.0 lbs.)

 

706*)mm

 

 

 

 

60/50 Hz

K1728-7

575

 

300A / 32V /100%

 

 

 

 

(36.7 kg.)

 

 

 

80 VDC

 

 

 

Advanced

1& 3 Phase

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Process

60/50 Hz

 

 

 

 

 

 

 

Advanced Process

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(81.5 lbs.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(37.0 kg.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Overall Length Including Handle, 27.8” (706mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V350-PRO INPUT CURRENT

 

 

 

 

 

 

Recommemded Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input 50/60 Hz

 

 

 

Output

 

 

 

Recommended

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

Phases

 

300Amps @

350Amps @

 

Line Cord

 

Fuse size

 

Notes

 

 

 

 

 

 

 

32Volts(100%)

34Volts(60%)

 

AWG

 

 

 

 

 

 

 

 

200

 

1

 

Not

 

Not

 

 

 

 

 

 

---

 

Note 1

 

 

 

 

 

 

 

Recommended

Recommended

 

 

 

 

 

 

 

 

 

 

 

208

 

1

 

76

 

94

 

 

 

2

 

125A

 

Note 2

 

 

 

230

 

1

 

69

 

85

 

 

 

4

 

125A

 

Note 2

 

 

 

380

 

1

 

Not

 

Not

 

 

 

 

 

 

---

 

Note 1

 

 

 

 

 

 

 

Recommended

Recommended

 

 

 

 

 

 

 

 

 

 

 

400

 

1

 

Not

 

Not

 

 

 

---

 

---

 

Note 1

 

 

 

 

 

 

 

Recommended

Recommended

 

 

 

 

 

 

 

 

 

 

 

415

 

1

 

41

 

64

 

 

 

6

 

80A

 

Note 2

 

 

 

460

 

1

 

36

 

42

 

 

 

8

 

70A

 

 

 

 

 

 

575

 

1

 

31

 

37

 

 

 

8

 

50A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

 

3

 

41

 

50

 

 

 

8

 

80A

 

Note 2

 

 

 

208

 

3

 

39

 

50

 

 

 

6

 

80A

 

Note 2

 

 

 

230

 

3

 

36

 

42

 

 

 

8

 

70A

 

 

 

 

 

 

380

 

3

 

23

 

28

 

 

 

8

 

50A

 

 

 

 

 

 

400

 

3

 

22

 

27

 

 

 

8

 

50A

 

 

 

 

 

 

415

 

3

 

22

 

26

 

 

 

8

 

50A

 

 

 

 

 

 

460

 

3

 

19

 

23

 

 

 

8

 

50A

 

 

 

 

 

 

575

 

3

 

16

 

18

 

 

 

8

 

35A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1. Not rated is indicated by 4-x’s in the box on the rating plate.

Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.

OUTPUT CABLES, CONNECTIONS AND LIMITATIONS

Select The output cable size based upon the following chart.

Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:

DUTY CYCLE

CURRENT

LENGTH UP TO 200FT.(61m)

200-250 FT. (61-76m)

100%

300

1/0

1/0

60%

350

1/0

2/0

 

 

 

 

V350-PRO

Page 8
Image 8
Lincoln Electric SVM158-A service manual Installation