ACCESSORIES
Return to Master TOC
Return to Master TOC
CONNECTION OF THE
PRO USING K480 CONTROL CABLE (SEE FIGURE C.5)
NOTE: AN
1.Remove input power to the
2.Connect the electrode cable from the K480 control cable to the “+” terminal of the welder and to the
NOTE: Figure C.5 shows the electrode connected for positive polarity. To change polarity, shut the welder off and reverse the electrode and work cables at the output terminals.
NOTE: Welding cable must be sized for current and duty cycle of application.
3.Connect the input cable from the K480 control cable to the (115VAC) 14 pin amphenol on the
4.Set the “VOLTMETER” switch to “+” or
5.Set “CONTROL SELECT” to “REMOTE”.
6.Set the “MODE” to the
7.Place the “WELD TERMINALS SELECT” in the “REMOTE” position.
8.Adjust wire feed speed at the
9.Set the “ARC” control at “0” initially and adjust to suit.
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Figure C.5 V350-PRO/LN-7 with K480 Control Cable Connection Diagram
|
| TO |
14 PIN |
| CABLE PLUG |
AMPHENOL |
|
|
(115VAC) |
| OPTIONAL K857 |
AT REAR OF |
| |
| REMOTE CONTROL | |
MACHINE |
| |
|
| |
- | + | K480 CONTROL CABLE |
6 PIN |
| ELECTRODE CABLE |
AMPHENOL |
| |
|
| TO WIRE FEED UNIT |
|
| TO WORK |