F-7

 

 

 

 

 

 

 

 

 

 

 

F-7

 

TROUBLESHOOTING & REPAIR

 

 

 

 

 

 

Observe Safety Guidelines

 

 

 

 

 

 

 

TROUBLESHOOTING GUIDE

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

 

 

 

 

The machine’s welding output is

1. Put the Control Select in the

1.

Perform

the

Current

 

very high and uncontrollable.

 

Local position. If the problem is

 

Transducer Test.

 

 

 

 

 

 

 

solved

the

remote

control

 

 

 

 

 

 

 

 

 

 

device

or

associated

circuitry

2.

If the output is normal

when

 

 

 

may be faulty.

 

 

 

 

the Control Select is in the Local

 

 

 

 

 

 

 

 

 

 

position but the output is very

 

 

2.

Check

for

proper

current and

 

high in the Remote position the

 

 

 

remote

board may be

faulty.

 

 

 

voltage calibration.

 

 

 

 

 

 

 

 

 

Perform

The

SPI

Cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Resistance and Voltage Test.

 

 

 

 

 

 

 

 

 

3. The control board may be faulty.

 

 

 

 

 

 

 

The Weld Mode Select does not

1.

Refer to Operation Section of

1. Check for loose or faulty plug

 

function properly.

 

this manual for normal operation

 

connections between the con-

 

 

 

characteristics.

 

 

 

trol board and the mode select

 

 

 

 

 

 

 

 

 

 

panel. See the wiring diagram.

 

 

NOTE: The mode panel is not pre-

 

 

 

 

 

 

 

 

 

 

sent

if

the

advanced

2.

Perform

the

SPI

Cable

 

 

 

process panel is installed.

 

Resistance and Voltage Test.

 

 

 

 

 

 

 

 

 

3. The Mode Select Panel board

 

 

 

 

 

 

 

 

 

 

may be faulty.

 

 

 

 

 

 

 

 

 

 

 

 

 

4. The control board may be faulty.

The output control and/or Weld 1.

Refer to Operation Section of

1.

Check for loose or faulty plug

Terminals Select functions do not

this manual for normal operation

 

connections between the

operate properly.

characteristics.

 

remote board and the weld/out-

 

 

 

put controls. See the wiring dia-

2.

Check for proper current and

 

gram.

 

voltage calibration.

 

 

 

 

2.

The Remote Board may be

 

 

 

faulty.

 

 

3.

The control board may be faulty.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353(WELD).