Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-95

TROUBLESHOOTING AND REPAIR

F-95

 

 

 

 

 

 

 

 

RETEST AFTER REPAIR

 

 

 

 

 

 

 

 

 

 

 

 

Test

Required Action

Expected Results

 

 

 

Steps

 

 

 

 

 

Lft.display

Rt. display

 

 

 

 

 

 

 

 

 

 

 

 

33

Adjust the remote output control potentiometer connect-

6-PIn roCP

HI

 

 

 

 

ed to the 6-pin amphenol connector to its highest set-

 

 

 

 

 

 

ting.

 

 

 

 

 

 

 

 

 

 

34

Adjust the remote output control potentiometer connect-

6-PIn roCP

Lo

 

 

 

 

ed to the 6-pin amphenol connector to its lowest set-

 

 

 

 

 

 

ting.

 

 

 

 

 

 

 

 

 

 

35

This will only appear if a trigger switch is already con-

6-PIn rIgr

oFF

 

 

 

 

nected to the 6-pin amphenol connector on the front of

 

 

 

 

 

 

the machine and the trigger switch is presently on.

 

 

 

 

 

 

Turn the trigger switch connected to the 6-pin amphenol

 

 

 

 

 

 

connector off.

 

 

 

 

 

 

 

 

 

 

36

Turn the trigger switch connected to the 6-pin amphenol

6-PIn Rigr

on

 

 

 

 

connector on.

 

 

 

 

37

Turn the trigger switch connected to the 6-pin amphenol

6-PIn rLgr

oFF

 

 

 

 

connector off.

 

 

 

 

 

 

 

 

 

 

38

This will only appear if a potentiometer is still connect-

dcon

6-PIn roCP

 

 

 

 

ed to the 6-pin amphenol connector. If this message

 

 

 

 

 

 

appears, disconnect the potentiometer from the 6-pin

 

 

 

 

 

 

amphenol connector.

 

 

 

 

39

This will only appear if a potentiometer is already con-

dcon

14-PIn roCP

 

 

 

 

nected to the 14-pin amphenol connector. If this mes-

 

 

 

 

 

 

sage appears, disconnect the potentiometer from the

 

 

 

 

 

 

14-pin amphenol connector.

 

 

 

 

40

Connect a remote output control potentiometer to the

con

14-PIn roCP

 

 

 

 

14-pin amphenol connector.

 

 

 

 

 

 

 

 

 

 

41

Adjust the remote output control potentiometer connect-

14-PIn roCP

HI

 

 

 

 

ed to the 14-pin amphenol connector to its highest set-

 

 

 

 

 

 

ting.

 

 

 

 

42

Adjust the remote output control potentiometer connect-

14-PIn roCP

Lo

 

 

 

 

ed to the 14-pin amphenol connector to its lowest set-

 

 

 

 

 

 

ting.

 

 

 

 

 

 

 

 

 

 

43

This will only appear if a trigger switch is already con-

14-PIn rIgr

oFF

 

 

 

 

nected to the 14-pin amphenol connector and the trig-

 

 

 

 

 

 

ger switch is presently on. Turn the trigger switch con-

 

 

 

 

 

 

nected to the 14-pin amphenol connector off.

 

 

 

 

 

 

 

 

 

 

44

Turn the trigger switch connected to the 14-pin amphe-

14-PIn rIgr

on

 

 

 

 

nol connector on.

 

 

 

 

 

 

 

 

 

45

Turn the trigger switch connected to the 14-pin amphe-

14-PIn rIgr

oFF

 

 

 

 

nol connector off.

 

 

 

 

 

 

 

 

 

 

 

 

 

V350-PRO

 

 

 

Page 145
Image 145
Lincoln Electric SVM158-A service manual Adjust the remote output control potentiometer connect