11.The back of the machine may now gently be pulled away to gain access to the current trans- ducer. Note: The rear of the machine cannot be removed completely.

12.Carefully swing the rear of the machine open to the left while facing the rear of the machine.

13.Perform the Snubber Board Removal Procedure.

14.Remove leads #X2 and #20 from the output diode module.

15.Remove leads #X4 and #40 from the other output diode module.

16.Using a 3/8” wrench, remove the three mounting screws from the output diode heatsink assembly. Take note placement of insulation for reassembly. See Figure F.42.

17.Cut any necessary cable ties and carefully remove the heavy lead from the diode heatsink using a 1/2” nut driver.

18.Remove the output diode heatsink assembly through the rear of the machine.

19.Remove plug #J90 from the current transducer.

20.Using a 3/8” nut driver, remove the two mounting nuts from the current transducer.

Return to Section

Return to Section TOC

Return to Section TOC

Return to Master

Return to Master TOC

Return to Master TOC

FIGURE F.42– OUTPUT HEATSINK MOUNTING SCREW LOCATION