Lincoln Electric SVM158-A + Probe, Input Rectifier Bridge Removal & Replacement procedure

Models: SVM158-A

1 167
Download 167 pages 56.76 Kb
Page 73
Image 73

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-23

F-23

TROUBLESHOOTING & REPAIR

INPUT RECTIFIER TEST (CONTINUED)

Table F.2 Input Rectifier Test Points

 

TEST POINT TERMINALS

 

ANALOG METER

 

 

X10 RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+ PROBE

 

 

Acceptable Meter Readings

 

- PROBE

 

 

 

 

 

 

 

A

207

 

Greater than 1000 ohms

 

B

207

 

Greater than 1000 ohms

 

C

207

 

Greater than 1000 ohms

 

A

207A

 

Greater than 1000 ohms

 

B

207A

 

Greater than 1000 ohms

 

C

207A

 

Greater than 1000 ohms

 

A

209

 

Less than 100 ohms

 

B

209

 

Less than 100 ohms

 

C

209

 

Less than 100 ohms

207

A

 

Less than 100 ohms

207

B

 

Less than 100 ohms

207

C

 

Less than 100 ohms

 

207A

A

 

Less than 100 ohms

 

207A

B

 

Less than 100 ohms

 

207A

C

 

Less than 100 ohms

209

A

 

Greater than 1000 ohms

209

B

 

Greater than 1000 ohms

209

C

 

Greater than 1000 ohms

 

 

 

 

 

 

Return to Section TOC

Return to Master TOC

9.If the input rectifier does not meet the acceptable readings outlined in Table F.2 the component may be faulty. Replace

Note: Before replacing the input rectifier, check the input power switch and per- form the Main Switch Board Test. Also check for leaky or faulty filter capacitors.

10.If the input rectifier is good, be sure to reconnect leads 207, 207A, and 209 to the correct terminals and torque to 31 inch lbs. Apply silicone sealant.

11.If the input rectifier is faulty, see the

Input Rectifier Bridge Removal & Replacement procedure.

12.Replace the case wraparound cover.

V350-PRO

Page 73
Image 73
Lincoln Electric SVM158-A service manual + Probe, Input Rectifier Bridge Removal & Replacement procedure