POWER BOARD TEST (CONTINUED)

Table F.3 Power Board Voltage Checks

 

 

 

 

 

NORMAL

CHECK POINT

TEST

CONNECTOR

LEAD NO.

ACCEPTABLE

VOLTAGE

LOCATION

DESCRIPTION

PLUG PIN NO.

OR IDENTITY

READING

 

 

 

 

 

POWER PC

CHECK 40VDC

 

2(+)

 

 

BOARD

SUPPLY FROM

 

1(-)

65 (+)

38-42 VDC

 

 

CONNECTOR

RECT. BRIDGE

 

 

66 (-)

 

PLUG J41

TO POWER BD.

65

66

 

 

 

 

 

 

POWER PC

CHECK +15VDC

 

1(+)

 

 

BOARD

SUPPLY FROM

 

5(-)

412 (+)

15 VDC

 

410

CONNECTOR

POWER PC

 

 

410 (-)

 

PLUG J42

BOARD

 

412

 

 

 

 

 

 

 

POWER PC

CHECK +5VDC

 

3(+)

 

 

 

 

 

 

 

BOARD

SUPPLY FROM

 

5(-)

408 (+)

5 VDC

 

410

CONNECTOR

POWER PC

 

 

410 (-)

 

PLUG J42

BOARD

408

 

 

 

POWER PC

CHECK -15VDC

 

2(+)

 

 

BOARD

SUPPLY FROM

 

5(-)

411 (+)

-15 VDC

 

410

CONNECTOR

POWER PC

 

411

410 (-)

 

PLUG J42

BOARD

 

 

 

 

POWER PC

CHECK +5VDC

 

3(+)

 

 

401

12(-)

403 (+)

5 VDC

BOARD

“SPI” SUPPLY

 

 

CONNECTOR

FROM POWER

 

 

401 (-)

 

PLUG J43

PC BOARD

 

403

 

 

POWER PC

CHECK +5VDC

 

 

 

 

4(+)

 

 

BOARD

“RS232”

 

9(-) 405

406 (+)

5 VDC

CONNECTOR

SUPPLY FROM

 

 

405 (-)

 

POWER PC

 

 

 

PLUG J43

 

 

 

 

BOARD

 

406

 

 

 

 

 

 

POWER PC

CHECK +15VDC

 

6(+)

 

 

401

12(-)

402 (+)

15 VDC

BOARD

“SPI” SUPPLY

 

 

 

CONNECTOR

FROM POWER

 

 

401 (-)

 

PLUG J43

PC BOARD

402

 

 

 

 

 

 

 

 

V350-PRO