Lincoln Electric SVM158-A service manual Perform the Snubber Board Replacement Procedure

Models: SVM158-A

1 167
Download 167 pages 56.76 Kb
Page 141
Image 141

TOC

F-91

F-91

TROUBLESHOOTING & REPAIR

CURRENT TRANSDUCER REMOVAL AND REPLACEMENT (continued)

Return to Section

Return to Section TOC

Return to Master

Return to Master TOC

21.Replace the current transducer.

22.Replace the two 3/8” mounting nuts previously removed.

23.Reconnect plug #J90 to the current transducer.

24.Replace any necessary cable ties previously cut.

25.From the rear of the machine, replace the heavy flex lead to the bottom of the output diode heatsink assembly using a 1/2” wrench. Note: Don’t forget to include all washers.

26.Replace the output diode heatsink assembly pre- viously removed using a 3/8” wrench.

Note: Be sure to place insulation in its original location.

27.Replace leads X2, #20, X4, # 40 previously removed from the two output diode modules. Torque to 30-40 inch lbs.

28.Perform the Snubber Board Replacement Procedure.

30.Using a 3/8” wrench, replace leads #202, #203, #206, and #207A previously removed from the reconnect switches.

31.Tighten the metal nut previously removed from the inside of the rear wall on the back of the machine. Channel locks may be necessary.

32.Replace the large plastic nut from around input power line located at the back of the machine.

33.Replace the five leads to the reconnect panel in their proper locations.

34.Replace the two CB2 circuit breaker leads previ- ously removed.

35.Using a 5/16” nut driver, replace the four screws at the bottom and right side of the rear assembly.

36.Replace the case wraparound cover.

37.Perform the Voltage and Current Calibration

Procedure.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

29.The rear of the machine may now be placed back into its original position.