F-96

TROUBLESHOOTING AND REPAIR

F-96

 

 

 

 

 

 

 

 

 

RETEST AFTER REPAIR

 

 

 

 

 

 

 

 

 

 

 

 

Test

Required Action

Expected Results

 

 

Steps

 

 

 

 

 

 

Lft.display

Rt. display

 

 

 

 

 

 

 

 

 

 

46

This will only appear if a potentiometer is still connect-

dcon

14-pIn roCP

 

 

 

ed to the 14-pin amphenol connector. If this message

 

 

 

 

 

 

 

appears, disconnect the potentiometer from the 14-pin

 

 

 

 

 

 

 

amphenol connector.

 

 

 

 

 

 

 

 

 

 

47

Test steps 21-24 verify the functionality of the gas sole-

GAS

On

 

 

 

noid. If an oscilloscope is available, verify that the cur-

 

 

 

 

 

 

 

rent flowing through the gas solenoid is zero before the

 

 

 

 

 

 

 

solenoid is energized, increases to approximately

 

 

 

 

 

 

 

700mA (pull in current), remains at 700 mA for approxi-

 

 

 

 

 

 

 

mately 150 msec, and decreases to approximately

 

 

 

 

 

 

 

200mA (hold current). Press the local/remote pushbut-

 

 

 

 

 

 

 

ton to turn the gas solenoid on.

 

 

 

 

<- 150msec - >

700mA +------------------------+

200mA

 

+-----....------+

0mA

 

 

 

+

 

 

+-------------

 

Or, the signal can be verified by measuring 12.3 VDC

 

 

+/- .5V from lead 553A to 554A (Lead 553A should be

 

 

positive)

 

 

 

 

48

Press the local/remote pushbutton again to turn the gas GAS

OFF

 

solenoid off.

 

After completing all of the above tests, the following will appear on the display.

 

 

Verify this message appears for approximately 3 sec-

DIAg

PASS

 

 

onds

 

 

 

 

 

 

 

V350-PRO

Page 146
Image 146
Lincoln Electric SVM158-A service manual Off