F-30

F-30

TROUBLESHOOTING & REPAIR

OUTPUT DIODE MODULES TEST (continued)

FIGURE F.5 Machine Output Terminals

AMPS

VOLTS

CONTROL

 

WELD TERMINALS

REMOTE

 

REMOTE

LOCAL

OUTPUT

ON

 

 

SELECT

SELECT

MEMORY BUTTON

SELECT ATTRIBUTE

SELECT KNOB

ADJUST ATTRIBUTE

_ +

NEGATIVE

POSITIVE

OUTPUT

OUTPUT

TERMINAL

TERMINAL

Return

Return

TEST PROCEDURE

1.Remove input power to the V350-PRO.

2.Locate the output terminals on the front panel of the machine. See Figure F.5.

3.Remove any output cables and load from the output terminals.

4.Using the analog ohmmeter test for more than 200 ohms resistance between positive and negative output terminals. Positive test lead to the positive terminal; Negative test lead to the negative terminal. See Figure

F.6.

NOTE: The polarity of the test leads is most important. If the test leads polarity is not cor- rect, the test will have erroneous results.