TROUBLESHOOTING AND REPAIR
VOLTAGE AND CURRENT CALIBRATION PROCEDURE (continued)
Return to Section
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master
Return to Master TOC
Return to Master TOC
Return to Master TOC
CALIBRATION CHECK
The calibration of the
1.Press and hold in the Mode Select button.
2.Turn on the
3.Rotate the output knob, while still holding the mode select button in, until the displays read “mode 200”. NOTE: Machines with an Advanced Process Panels do not have a mode select button. Use the same procedure except hold in the Memory button on the advanced process panel instead of the mode select but- ton.
4.Release the Mode Select/Memory button and the machine will be in mode 200.
5.With the machine in mode 200 apply a resistive load to the welding output terminals (approxi- mately .087 ohms) set the machine output to 300 amps and enable the Weld Terminals. (Weld Terminals Select ON).
6.Using the test meters note the output voltage and current.
7.The
8.The
9.If the voltmeter does not meet the specification then proceed to the Voltage Calibration
Procedure.
10.If the ammeter does not meet the specification then proceed to the Current Calibration
Procedure.
NOTE: Before attempting to calibrate the voltage or current setting of the
VOLTAGE CALIBRATION
1.Connect the resistive load band (approximate- ly .087 ohms) and test voltmeter to the welding output terminals.
2.Press and hold in the Mode Select/Memory button.
3.Turn on the
4.Rotate the Output Control knob until the dis- play reads “vol cAL”.
5.Release the Mode Select/Memory button.
6.Adjust the output control knob until the actual output voltage reading on the test volt meter is 20volts
7.Wait for the machine’s output to be automati- cally turned off and then back on.
8.Adjust the Output Control knob again if neces- sary to make the actual voltage output 20 volts
9.Wait for the machine’s output to be automati- cally turned off and then back on.
10.Repeat the above two steps if necessary.
11.Press and release the Mode Select/Memory button to save the calibration.
NOTE: If the Mode Select/Memory button is not pressed within 30 seconds after adjusting the Output Control knob the machine will leave the calibration mode and use the previous cal- ibration settings.