Lincoln Electric SVM158-A service manual Output Rectifier Modules, Removal and Replacement

Models: SVM158-A

1 167
Download 167 pages 56.76 Kb
Page 134
Image 134

Section TOC

Master TOC

F-84

F-84

TROUBLESHOOTING & REPAIR

OUTPUT RECTIFIER MODULES

REMOVAL AND REPLACEMENT (continued)

Return to

Section TOC

Return to

Master TOC

PROCEDURE

1.Remove input power to the V350-PRO.

2.Using a 5/16” nut driver remove the case wrap- around cover.

3.Perform the Input Filter Capacitor Discharge Procedure detailed earlier in this section.

4.Locate the output diode modules located behind the snubber board. See figure F.38.

5.Before the output rectifier modules can be reached, the Snubber Board Removal Procedure must be performed.

6.After the snubber board is removed, remove the four leads connected to the modules using a 3/16” allen wrench. These leads are #X4, #X2, #20, #40. Note their positions for reassembly. See Figure

F.39.

7.Remove the copper plates from the tops of the modules.

Return to

Return to Section TOC

Return to Section TOC

Return to

Return to Master TOC

Return to Master TOC

FIGURE F.38. – OUTPUT RECTIFIER MODULE LEAD LOCATIONS

Output Diode

Modules

Snubber

Board

LEFT SIDE

V350-PRO