Lincoln Electric SVM158-A service manual Remote Control

Models: SVM158-A

1 167
Download 167 pages 56.76 Kb
Page 31
Image 31

C-5

C-5

ACCESSORIES

Return to Master TOC

Return to Master TOC

CONNECTION OF THE LN-25 TO THE V350-PRO “ACROSS THE ARC” WITH OPTIONAL 6 PIN K857 REMOTE CON- TROL.

1.Remove input power to the V350-PRO.

2.Connect the electrode cable to the output terminal of polarity required by the electrode. Connect the work lead to the other terminal. Welding cable must be sized for current and duty cycle of the application.

3.Connect the K857 remote control to the 6-pin amphenol on the V350-PRO.

4.Attach the single lead from the LN-25 control box to the work using the spring clip on the end of the lead. This is only a control lead - it carries no welding current.

5.Set the voltmeter switch to the electrode polarity chosen.

6.Set “CONTROL SELECT” to “REMOTE”.

7.Set the “MODE” to the “CV-WIRE” position.

8.Set “WELD TERMINALS SELECT” to the “ON” position.

CAUTION

If you are using an LN-25 without an internal con- tactor, the electrode will be “HOT” when the V350- PRO is energized.

9.Set the “ARC CONTROL” to the “O” position and then adjust to suit.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Figure C.2 V350-PRO/LN-25 ACROSS THE ARC CONNECTION DIAGRAM WITH K857

REMOTE CONTROL

 

K857

6 pin

Remote Control

 

Amphenol

 

 

 

LN-25

+

-

Wire Feeder

Work Clip Lead

 

 

 

 

To Work

 

 

To Work

 

 

Electrode Cable

NOTE: Illustration shows electrode connected for negative polarity.

V350-PRO

Page 31
Image 31
Lincoln Electric SVM158-A service manual Remote Control