Installation Procedure for High Wattage Insulated Ceiling

 

Frame-In Kits 100IFIC, 1101FIC, 2001FIC

Read and understand these instructions before installing fixture.

This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.

Retain these instructions for maintenance reference.

New Construction

NOTE: I.C. Frame-In Kit may be used in direct contact with insulation.

Fig. A

Fig. B

Fig. C

Fig. D

Fig. E

Fig. F

Frame-In

Wire-In

Swing-Up

Close-In

Snap-On

Push-Up

Warning: Use Only With Lightolier Reflector Trims Marked With I.C. Lamping Information.

Use of Other Manufacturers’ Trims Voids the Underwriters Laboratories Listing and Could Constitute A Fire Hazard

1.  FRAME-IN (Fig. A)

Locate fixture along joist and line up bottom edge of HINGED MOUNTING BAR with the bottom of joist and fasten in place.

5 3/4" 2001FR

5 1/4" 1004ICX

BEND AT HOLE

tAB

 

5 5/8" 1101FIC

5 7/8" 2001FIC

6 3/8" 1001FIC

6" 1101FIC

Center line of aperture opening

BEND AT tAB

For suspended ceilings:

• Rotate HINGED BAR ENDS to position shown and fully extend bars.

Crimp bottom of edge of CHANNEL to prevent rotation of

 

HINGED BAR ENDS.

Bend NON-HINGED end of mounting bar at featured hole location and

 

extend out.

Note: Integral nail version available

hinged mounting bar

For Joist Spacing Less Than 16" On Center (To 12" On Center):

MOUNTING BAR CHANNELS can be shortened and used as nailing legs in tight spaces. Simply remove INNER BAR from holed CHANNEL, bend CHANNEL at appropriate point and use extra screw to secure it to the joist. (Fig. G)

Position notched area of MOUNTING BARS onto T-BAR and lock by

 

bending TAB underneath T-BAR BEAD as shown.

For suspended ceiling, make certain that bottom of Mounting Frame is no

 

higher than 1" above ceiling line.

hinged bar ends

t-bar

channel

 

tAB

 

Fig. G