Desa BY70CEB Service Procedures, Upper Shell Removal, Fuel Filter, 35/70,000 Btu/Hr Models

Page 8

R

PORTABLE FORCED AIR HEATERS

SERVICE

PROCEDURES

WARNING: Never service heater while it is plugged in, op- erating, or hot. Severe burns and electrical shock can occur.

Upper Shell Removal

1.Remove screws and lock washers along each side of heater using 5/16" nut- driver. These screws attach upper and lower shells together.

2.Lift upper shell off.

3.Remove fan guard.

Fuel Filter

(35/70,000 Btu/Hr Models)

1.Remove side cover screws using 5/16" nut-driver.

2.Remove side cover.

3.Pull rubber fuel line off fuel filter neck.

4.Carefully pry bushing and fuel filter out of fuel tank.

5.Wash fuel filter with clean fuel and re- place in tank.

6.Attach rubber fuel line to fuel filter neck.

7.Replace side cover.

Fuel Filter

Upper Shell

Upper

 

Shell

 

Fan

 

Guard

Fan

Guard

Figure 7 - Upper Shell Removal, 35/70,000

Figure 8 - Upper Shell Removal, 100/

Btu/Hr Models

150,000 Btu/Hr Models

Fuel Filter

 

Side Cover

Fuel Line

Figure 9 - Fuel Filter Removal, 35/70,000 Btu/Hr Models

(100/150,000 Btu/Hr Models)

1.Remove side cover screws using 5/16" nut-driver.

2.Remove side cover.

3.Pull upper fuel line off fuel filter neck.

4.Carefully pry bushing, lower fuel line, and fuel filter out of fuel tank.

5.Wash fuel filter with clean fuel and re- place in tank.

6.Attach upper fuel line to fuel filter neck.

7.Replace side cover.

Fuel Filter, Bushing, and Lower Fuel Line

Upper Fuel Line

Side Cover

Figure 10 - Fuel Filter Removal, 100/150,000 Btu/Hr Models

8

103618

Image 8
Contents Portable Forced AIR Heaters Safety Information Portable Forced AIR HeatersProduct Identification UnpackingAssembly FuelsVentilation Tools NeededExtension Cord Wire Size Requirements Theory OperationTo Start Heater To Stop HeaterPreventative Maintenance Storing TRANSPORTING, or ShippingSchedule How Often How ToTroubleshooting Observed Fault Possible Cause RemedyService Procedures Upper Shell RemovalFuel Filter 35/70,000 Btu/Hr ModelsSpark Plug 35,000 Btu/Hr Model70/100/150,000 Btu/Hr Models 70/100,000 Btu/Hr ModelsPump Pressure Adjustment Air Output, Air Intake, and Lint FiltersNozzle Removing Air and Fuel Line Hoses, 35,000 Btu/Hr ModelProcedure if rotor is binding Pump RotorFan SpecificationsWiring Diagrams 35,000 Btu/Hr Model Motor and Pump AssemblyIllustrated Parts Breakdown Parts List Desired part70,000 Btu/Hr Model Burner Head AssemblyMotor and Pump Assembly FHPF3-5C 100,000 Btu/Hr Model Lock Washer, #10 HA3019 Photocell Assembly 150,000 Btu/Hr Model Lock Washer, #10 099229-01 Photocell Bracket 100,000 150,000 AccessoriesWheels Handles EC Conformity Declaration EC Conformity Declaration SGB YoungmanWarranty and Repair Service