IF GAS LEAK OCCURS
SPECIFICATIONS
!WARNING
If you detect a gas leak, turn off propane supply at once. Ventilate the area. Wait until five minutes after propane odor is not present. Follow steps below to check for gas leak.
!WARNING
Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
1.After turning off propane supply and ventilating area, unplug heater power cord.
2.Turn propane supply on.
3.Apply a mixture of liquid soap and water to hose and connections between propane tank(s) and heater inlet. Bubbles forming show a leak.
4.Turn propane supply off and ventilate the area. Repair leak.
5.Wait until five minutes after propane odor is not present before restarting heater.
6.If you cannot repair leak, contact you local service center.
Model | BLP35ES |
Electrical Input | 220/240 volt, 50 hertz, 55 watts IP20 |
Maximum Input, net | 10.3 KW at 27 millibar |
Regulator Output | 27 millibar |
Burner Rate | 10.3 KW, 796 g/hr |
Supply Pressure (min.) | 2 bar |
Ventilation | 260 cm2 |
Room Size | 103 cubic meters |
Air Delivery Class | Type A |
Temperature Range for Heater Operation |
*When running heater in temperatures above 29° C, high internal temperatures may cause thermal limit device to shut down heater.