Desa BLP35ES owner manual Ignitor, Causing severe burns

Page 14

Ignitor

1.

Remove motor and fan

 

guard from heater (see

 

Motor, page 10, steps 1 and

 

2).

2.

Remove black ignitor wire

 

from piezo ignitor. Access

 

ignitor wire through

 

underside of heater base

 

(see Figure 13). Push wire

 

up through bushing in

 

heater shell.

3.

Remove ignitor mounting

 

screw from rear head using

Ignitor Wire

Piezo Ignitor

Bushing

Underside of Heater Base

 

nut-driver or standard

 

screwdriver (see Figure 14).

4.

Remove ignitor from rear

 

head.

5.

Install new ignitor. Attach

 

ignitor to rear head with

 

ignitor mounting screw.

6.

Run ignitor wire from new

 

ignitor through bushing in

 

heater shell. Attach ignitor

 

wire to piezo ignitor.

7.

Set gap between ignitor

 

electrode and target plate to

 

4.3 mm (see Figure 15).

8.

Test for spark.

 

WARNING: Make sure

 

heater is disconnected

 

from propane supply.

 

Heater could ignite

 

causing severe burns.

 

Push piezo ignitor button

 

and watch for spark be-

 

tween ignitor electrode and

 

target plate.

9.

Place motor and fan guard

 

into rear of heater shell (see

 

Motor, page 10, steps 9 and

 

10).

12

Figure 13 - Removing Ignitor Wire from Piezo Ignitor

Rear

Head

Ignitor

Ignitor

Mounting

Screw

Figure 14 - Removing Ignitor Mounting Screw and Ignitor

Target

Plate

Gap

Area

Ignitor

Electrode

Figure 15 - Clearance between Ignitor Electrode and Target Plate

Image 14
Contents Propane Construction Heater Page Propane Construction Heater Contents Safety Information Safety Information Unpacking Theory Operation Model BLP35ESPropane Supply Installation Regulator PositionInstallation Ventilation Operation To Start HeaterTo Change Propane Tanks To Stop HeaterTo Restart Heater Storage Maintenance Disconnect heater from propane supply tanksObserved Fault Possible Cause Remedy TROUBLE- ShootingMotor Service ProceduresElectrical System Fan Removing Fan Nut from Motor ShaftCausing severe burns IgnitorIf GAS Leak Occurs Illustrated Parts Breakdown Parts List Number and description of the desired partWarranty and Repair Service Keep this Warranty Limited WarrantyBaustellen Propanheizgerät Inhalt SICHERHEITS- Hinweise Abschnitt SeiteWarnhinweise Fortsetzung Arbeitsweise AuspackenProdukt Versorgung MIT Propangas Montage AchtungBedienung Einschalten des Heizgerä tsWechseln der Propangasflaschen Ausschalten des Heizgerä tsWiedereinschalten des Heizgerä ts Lagerung Wartung VorsichtFehlersuche Beobachtete MÖ Gliche STÖ Rung Ursache AbhilfeWARTUNGS- Massnahmen Elektrisches SystemVentilator Zü nder VerursachenTechnische Daten Illustrierter Teilekatalog Lieferbare Teile Nicht Abgebildet Garantie UND Reparaturdienst Page 100483-01 Rev. a 11/92