In addition to meeting noncombustible material clearances, you must also meet required clearances between fireplace opening and mantel shelf.Ifyoudonotmeettheclearanceslistedbelow,youwillneedahood.

Determining Minimum Mantel Clearance

If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).

Determining Minimum Mantel Clearance When Using a Hood

If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clearances shown in Figure 7 when using hood.

NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.

NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following:

operate the logs only with the flue damper open

raise the mantel to an acceptable height

remove the mantel

Mantel Shelf

12"

Underside of

 

10"

 

 

 

 

Mantel Shelf

 

 

 

 

 

 

 

 

8"

 

 

 

 

 

 

 

 

 

 

 

 

6"

 

 

 

 

 

 

 

 

 

 

 

 

2 1/2"

 

 

 

 

All minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

distances are

Minimum Non-

 

 

 

 

 

 

in inches

 

 

 

 

 

 

 

Combustible

 

 

 

 

 

 

 

Material

 

 

8"

12"

15"

18"

20"

 

 

 

 

 

Min.

 

 

 

 

 

 

 

 

 

 

 

Top of Fireplace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Opening

Hood

Distances to

(GA6050, GA6052,

Underside of

or GA6053)

Mantel

 

Figure 7 - Minimum Mantel Clearances When Using Hood

FLOOR CLEARANCES

A.If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).

B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combustible floor- ing (see Figure 9).

10"

Mantel Shelf

8"

6"

2 1/2"

Minimum Non-

(A)

 

 

 

Combustible

 

 

 

 

 

 

 

Material

12"

18"

20"

22"

 

 

8"

8"

14"

17"

 

Minimum Non-

Distances to

 

Combustible

 

Underside of

 

Material Height

Mantel

 

 

 

Combustible

Underside of

14"

Material

 

Mantel Shelf

Min.

 

All minimum

Noncombustible Material

Figure 8 - Minimum Fireplace Clearances If Installed at Floor Level

distances are

in inches

 

 

Log Set

24" 24"/30"/36" Models

20" 18" Model

Top of Fireplace

Opening

Hearth

Combustible Material

5"

Min.

Figure 6 - Minimum Mantel Clearances Without Using Hood

Figure 9 - Minimum Fireplace Clearances Above Combustible

Flooring

For morevisit www..com

111515-01C

Image 9
Contents What to do if YOU Smell GAS OWNER’S Operation Installation ManualSafety Information Table of ContentsUnpacking Local CodesProduct Features Product IdentificationAIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Check GAS TypeLOG Sizing Requirements Minimum Noncombustible Material Clearances If Not Using MantelMantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Area of Various StandardInstalling Battery into Remote Installing Batteries in ReceiverSure regulator Connecting to GAS SupplyPressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Rear Log Log #1 Placement Installing LogsFor Your Safety Read Before Lighting Operating HeaterLighting Instructions HAND-HELD Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterPilot Flame Pattern Inspecting BurnersBurner Primary AIR Holes Main BurnerCleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement Illustrated Parts Breakdown ModelsLDL3930NR and LDL3930PR Parts List Replacement Parts SpecificationsWiring Diagram Service Hints Technical ServiceOwners Registration Form Postage Required Accessories Warranty Information

LDL3924PR, LDL3930NR, LDL3930PR specifications

Desa LDL3924PR, LDL3930PR, and LDL3930NR represent a comprehensive range of innovative HVAC solutions. Each model is engineered to provide efficient heating and cooling in residential and commercial applications, ensuring optimal thermal comfort throughout the year.

The LDL3924PR model stands out with its advanced inverter technology, enabling variable speed operation that adjusts according to the heating or cooling demand. This not only enhances energy efficiency but also promotes quieter operation, making it ideal for residential settings. By seamlessly adapting to temperature fluctuations, users experience consistent comfort without the energy spikes often associated with conventional systems.

Similarly, the LDL3930PR model incorporates robust features such as high SEER (Seasonal Energy Efficiency Ratio) ratings, which indicate superior energy efficiency during cooling cycles. This model is specifically designed to work efficiently even in extreme weather conditions, maintaining performance in both high temperatures and colder climates. The extended lifespan of the compressor is another hallmark, thanks to its advanced protection mechanisms and durable construction materials.

The LDL3930NR is particularly notable for its eco-friendly refrigerant, which significantly reduces greenhouse gas emissions while maintaining excellent cooling efficiency. This model focuses on sustainable cooling solutions, aligning with global initiatives to combat climate change. With a sleek design, it blends seamlessly into modern spaces, making it a popular choice for aesthetic-conscious consumers.

All three models boast user-friendly interfaces, enabling easy control and customization of settings. Smart capabilities are integrated into the design, allowing for remote access and monitoring via mobile applications. This feature empowers users to adjust settings from anywhere, optimizing energy usage and ensuring comfort is always within reach.

In addition, these models include multi-stage filtration systems that not only enhance indoor air quality but also reduce allergens and pollutants. With low operating noise levels and aesthetically pleasing designs, the Desa LDL series is capable of enhancing any environment while promoting energy efficiency.

Whether for residential or commercial use, Desa's LDL3924PR, LDL3930PR, and LDL3930NR models exemplify the perfect integration of technology, efficiency, and user-centric design principles, making them top choices in the modern HVAC market.