Desa MPF24VNA Check GAS Type, Installation and Clearances, Flue Opening Specifications

Page 6

INSTALLATION

Continued

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not instal in fireplace. Call dealer where you bought the appliance for proper type of appliance.

WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion is not permitted.

INSTALLATION AND CLEARANCES

Figure 2 shows technical information regarding the installation of your gas log set. Please make sure all specifications shown are applicable before installation is attempted.

 

 

SPECIFICATIONS (W.C.)

 

 

 

FUEL INLET

MANIFOLD

 

 

PRESSURE

PRESSURE

 

 

 

Min.

Max.

 

 

NG

 

7"

10.5"

3.5"

 

LP

 

11"

14"

10"

 

Figure 2 - Technical Information Chart

FLUE OPENING SPECIFICATIONS

Note: This vented appliance must be installed only

in a solid-fuel burning or UL127 factory-built fire-

place constructed of noncombustible material and

connected to a working flue. The fireplace chimney

must have a permanent vent opening to outside

with minimum openings shown in Figure 3.

 

 

 

 

 

 

LOG SIZING REQUIREMENTS

 

 

 

 

 

 

 

MINIMUM FIREBOX SIZE

 

LOG

 

 

FRONT REAR* MIN. FLUE

SIZE HEIGHT DEPTH WIDTH WIDTH

SIZE

18"

 

20"

14"

25"

20.5"

6.5"

24"

 

20"

14"

29"

24.5"

6.5"

*Measured at 14" depth

 

 

 

Figure 3 - Sizes and Clearances

VENTING SPECIFICATIONS FOR

INSTALLATION

 

 

 

The fireplace chimney flue and vent must be draft-

ing properly. To check the vent for proper drafting:

Light a tightly rolled newspaper on one end and

place it at the inside front edge of the fireplace.

Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills out into the room, extinguish the flame and remove any obstruction until proper venting is achieved.

The chimney flue damper must be fixed open to pro- vide a minimum of 32 square inch of free air opening at all times during operation of the log set. A damper clamp is included to secure the damper.

The minimum flue sizes shown in Figure 3 are based on a 6' chimney height using round pipe. Your minimum flue size will vary based on input rate and chimney height. Refer to the National Fuel Gas Code ANSI Z223.1/NFPA 54, Section 6.6 for details.

INSTALLING DAMPER CLAMP

Secure the damper stop clam to the edge of the

damper as shown in Figure 4. If for any reason

this clamp doesn't work on your fireplace, another

suitable clamp or permanent stop must be installed,

or the damper blade must be cut or removed.

Damper

 

Clamp

Damper

 

Damper

 

Clamp

 

Damper

Damper

Masonry

Manufactured

Fireplace

Fireplace

Figure 4 - Attaching Damper Clamp

INSTALLING REMOTE CONTROL

ACCESSORY BRACKET

If installing optional remote control accessory you

will need to install the remote accessory bracket

for the receiver.

 

Use screws provided to attach bracket to valve

bracket as shown in Figure 5.

Follow installation instructions included with

remote accessory.

 

Valve Bracket

 

Remote

 

Bracket

 

Figure 5 - Attaching Remote Bracket to

Valve Bracket

6

www.desatech.com

114925-01B

Image 6
Contents What to do if YOU Smell GAS MPF24VNA, MPF24VPA MPF18VNA and MPF18VPATable of Contents Safety Information Local Codes High traffic areas Windy or drafty areasProduct Features InstallationProduct Identification Venting Specifications for Installation and ClearancesFlue Opening Specifications InstallationInstalling Appliance Connecting to GAS SupplyInstallation Items Needed Natural From Gas Meter 5 W.C.** to 10.5 W.C. Pressure Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Propane/LPPlacement of Loose Embers Pressure Testing Appliance Gas ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Operating Appliance Inspecting Burners Pilot Flame PatternON/OFF Series Model Ghrcb Technical Service Service HintsCleaning Maintenance Replacement PartsTroubleshooting Observed Problem Possible Cause RemedySee Wiring Diagram, Maintenance, Gas leak. See Warning Statement at topGas leak. See Warning statement at top Specifications AccessoriesWiring Diagram Illustrated Parts Breakdown MPF24VNA, MPF24VPA MPF18VNA, MPF18VPAParts List Warranty Information Keep this WarrantyLimited Warranty Vented GAS LOG Appliances

MPF24VNA specifications

Desa MPF24VNA is a high-performance, versatile appliance designed to meet the demands of modern heating solutions. This innovative product stands out due to its advanced features, making it an excellent choice for both residential and commercial applications.

One of the key characteristics of the Desa MPF24VNA is its energy efficiency. With a heating capacity of up to 24,000 BTUs, it can effectively warm spaces while using minimal energy, which is crucial for reducing heating costs. The unit is designed with a focus on environmentally friendly operation, helping users to lower their carbon footprint while still enjoying optimal comfort.

The technology employed in the Desa MPF24VNA is remarkable. It features a powerful, quiet fan system that ensures even heat distribution, eliminating cold spots in the room. This fan operates on multiple speeds, allowing users to tailor the airflow to their specific needs. Furthermore, the unit is equipped with a digital thermostat that provides precise temperature control, enabling users to set their desired comfort level with ease.

Another important feature is the user-friendly interface. The Desa MPF24VNA comes with a remote control, allowing users to adjust settings from a distance. This convenience is particularly beneficial in larger spaces where the heater may not be easily accessible. The programmable settings also help users to create heating schedules that align with their routines, further enhancing energy efficiency.

The design of the Desa MPF24VNA is both stylish and functional. Its sleek appearance allows it to blend seamlessly into various interior decors, making it an attractive heating solution for any space. Built with high-quality materials, the unit is not only durable but also designed for easy maintenance. The air filter is easily accessible and can be cleaned or replaced without hassle, ensuring that the heater operates at peak performance.

Safety is another priority with the Desa MPF24VNA. It includes several safety features such as an automatic shut-off function in case of overheating and a tip-over switch that turns the heater off if it is knocked over. This ensures peace of mind for users, especially in households with children or pets.

In conclusion, the Desa MPF24VNA is a top-tier heating appliance that combines efficiency, technology, and safety for optimal performance. Its versatile features make it an ideal choice for anyone looking to enhance their heating solutions while maintaining a focus on sustainability and comfort.