Desa SCIVFB, SCIVFR, SCIVFG, SCIVFC installation manual Variable Control Operation

Page 20
C-clockwise
C-clockwise

OPERATING HEATER

Continued

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information on page 18 . If you don’t smell gas, go to the next step.

5. Slightly depress and turn control knob counterclockwise to the PILOT position. Keep control knob pressed in for five (5) seconds (see Figure 22, page 19).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the burner (see Figure 16, page 14). If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not light, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure on page 21.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Thermocouple

Ignitor Electrode

Pilot Burner

20

Figure 23 - Pilot

8. Slightly depress and turn control knob counterclockwise to the HIGH position. The burner should light. Set control knob to any heat level between HIGH and LO.

VARIABLE CONTROL OPERATION

The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realistic, dancing yellow flames. Selecting higher settings produces greater heat output. This results in increased heating comfort.

WARNING

WARNING ICON

G 001

Do not operate heater between PILOT and HIGH positions.

CAUTION

WARNING ICON

G 001

Do not try to adjust heating levels by using the manual shutoff valve.

104025

Image 20
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Burner patterns can cause sooting Local Codes Product Features Safety PilotOperation Piezo Ignition SystemProviding Adequate Ventilation AIR for CombustionVentilation Determining if You Have a Confined or Unconfined Space AIR for Combustion and VentilationDetermining AIR Flow for Heater Location AIR for Ventilation AIRMinimum Wall and Ceiling Clearances see Figure InstallingCheck GAS Type Stove Cavity Assembly Front ViewTop View Side ViewLaying Down Stove On Side Attaching Stove Legs Attaching Stove Door Installing Installing GAS LOG Heater Into Stove Placing Heater Base In Stove CavityInstalling One-Piece Stove Log Set Connecting to GAS Supply Back ViewExternal Regulator With Vent Pointing Down Connecting it to gas piping and/or fittings Checking GAS ConnectionsPressure Testing Heater Gas Connections Manual Shutoff ValveFor Your Safety Read Before Lighting Operating HeaterVariable Control Operation Operating Heater Inspecting Burners Pilot Flame PatternCleaning and Maintenance Trouble Shooting Turn off heater and let cool before cleaningODS/PILOT and Burner LogsCleaning and Mainte Trouble Shooting TROUBLE- Shooting Statement at topTechnical Service Service Hints Replacement PartsAccessory Valve GA5010Illustrated Parts Breakdown Parts List SCIVFC, Scivfb SCIVFG, Scivfr SCIVFC, Scivfb Warranty Information VENT-FREE Propane GAS LOG Heaters and AMITYä Stove Chassis