TROUBLE-
SHOOTING
Continued
24
OBSERVED | POSSIBLE |
|
|
| |
PROBLEM | CAUSE | REMEDY |
| ||
|
|
|
|
|
|
Burner does not light | 1. | Inlet gas pressure is | 1. | Contact local propane/ |
|
after ODS/pilot is lit |
| too low |
| LP gas company |
|
| 2. | Burner orifice clogged | 2. | Clean burner (see |
|
|
|
|
| Cleaning and Mainte- |
|
|
|
|
| nance, page 22) or |
|
|
|
|
| replace burner orifice |
|
| 3. | Burner orifice diameter | 3. | Replace burner orifice |
|
|
| is too small |
|
|
|
|
|
|
|
|
|
Delayed ignition | 1. | Manifold pressure is | 1. | Contact local propane/ |
|
burner |
| too low |
| LP gas company |
|
| 2. | Burner orifice clogged | 2. | Clean burner (see |
|
|
|
|
| Cleaning and Mainte- |
|
|
|
|
| nance, page 22) or |
|
|
|
|
| replace burner orifice |
|
|
|
|
|
|
|
Burner backfiring | 1. | Burner orifice is | 1. | Clean burner (see |
|
during combustion |
| clogged or damaged |
| Cleaning and Mainte- |
|
|
|
|
| nance, page 22) or |
|
|
|
|
| replace burner orifice |
|
| 2. | Damaged burner | 2. | Replace damaged |
|
|
|
|
| burner |
|
| 3. | Gas regulator defective | 3. | Replace gas regulator |
|
|
|
|
|
| |
Slight smoke or odor | 1. Not enough air | 1. | Check burner for dirt |
| |
during initial opera- |
|
|
| and debris. If found, |
|
tion |
|
|
| clean burner (see |
|
|
|
|
| Cleaning and Mainte- |
|
|
|
|
| nance, page 22) |
|
| 2. | Gas regulator defective | 2. | Replace gas regulator |
|
| 3. | Residues from manu- | 3. | Problem will stop after |
|
|
| facturing processes |
| a few hours of opera- |
|
|
| and logs curing |
| tion |
|
|
|
|
|
| |
Heater produces a | 1. Turning control knob | 1. | Turn control knob to |
| |
whistling noise when |
| to HI position when |
| LO position and let |
|
burner is lit |
| burner is cold |
| warm up for a minute |
|
| 2. | Air in gas line | 2. | Operate burner until air |
|
|
|
|
| is removed from line. |
|
|
|
|
| Have gas line checked |
|
|
|
|
| by local propane/LP |
|
|
|
|
| gas company |
|
| 3. | Air passageways on | 3. | Observe minimum |
|
|
| heater blocked |
| installation clearances |
|
|
|
|
| (see pages |
|
| 4. | Dirty or partially | 4. | Clean burners (see |
|
|
| clogged burner orifice |
| Cleaning and Mainte- |
|
|
|
|
| nance, page 22) or |
|
|
|
|
| replace burner orifice |
|
|
|
|
|
|
|
Moisture/condensation | 1. | Not enough combus- | 1. | Refer to Air for Com- |
|
noticed on windows |
| tion/ventilation air |
| bustion and Ventilation |
|
|
|
|
| requirements (page |
|
104025