UNVENTED (VENT-FREE) GAS LOG HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

For more information, visit www.desatech.com

VF-24N-EMU

VF-24P-EMU

VF-18N-EMU

VF-18P-EMU

ANSI Z21.11.2-2002

 

Approved

Certified

 

Design Dynamics Vent-free Models Also Design-Certified As Vented Decorative Appliances

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, per- sonal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas sup- plier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

WARNING: Improper installation, adjust- ment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a quali- fied installer, service agency, or the gas supplier.

WARNING: This appliance is for instal- lation only in a solid-fuel burning masonry or UL127 factory-built fireplace, or in an approved ventless firebox. It is design- certified for these installations in accor- dance with ANSI Z21.11.2. Exception: Do not install this appliance in a factory-built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs.

WARNING:This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation section on page 4 of this manual.

This appliance may be installed in an aftermarket,* manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate.This appliance is not convertible for use with other gases.

Warning: This product must be installed by a Licensed Plumber or Gas Fitter when installed within The Commonwealth of Massachusetts.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Image 1
Contents What to do if YOU Smell GAS VF-24N-EMU VF-24P-EMU VF-18N-EMU VF-18P-EMUSafety Information Table of ContentsProduct Identification Product IdentificationProduct Features Optional Remote Control AccessoriesLocal Codes UnpackingConfined and Unconfined Space Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation and Clearances for VENT-FREE Operation InstallationCheck GAS Type Minimum Noncombustible Material Clearances If Not Using MantelMantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Area of Various Standard Round FluesConnecting to GAS Supply Pressure Testing Heater Gas Connections Pressure Testing gas Supply Piping systemChecking GAS Connections Checking Gas Joints propane/LP only Operating Heater For Your Safety Read Before LightingLighting Instructions Remote Control Operation Manual Lighting ProcedureTo Turn OFF GAS to Appliance Selector Toggle Switch Optional Remote Control Pilot Flame Pattern Inspecting BurnersBurner Flame Pattern Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement at VF-18N-EMU VF-24N-EMU SpecificationsService Hints Wiring DiagramTechnical Service Replacement PartsIllustrated Parts Breakdown Log sets and mounting plates are ordered as an assemblyVF-24N-EMU Parts List Parts ListAccessories This page Intentionally Left Blank Owners Registration Form Postage Required 111826-05 Warranty Information