Desa VF-24P-EMU, VF-18P-EMU installation manual Specifications, VF-18N-EMU VF-24N-EMU

Page 22

22

SPECIFICATIONS

SPECIFICATIONS

 

VF-18N-EMU

VF-24N-EMU

Btu (Variable)

24,000/36,000

25,000/39,000

Type Gas

Natural Gas Only

Natural Gas Only

Ignition

Piezo

Piezo

Manifold Pressure

3.5" W.C.

3.5" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

10.5" W.C.

10.5" W.C.

Minimum*

5.0" W.C.

5.0" W.C.

Shipping Weight

32 lbs.

34 lbs.

* For purpose of input adjustment

 

 

VF-18P-EMU

VF-24P-EMU

Btu (Variable)

24,000/36,000

25,000/39,000

Type Gas

Propane/LP Only

Propane/LP Only

Ignition

Piezo

Piezo

Manifold Pressure

10" W.C.

10" W.C. - 3.4" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

14" W.C.

14" W.C.

Minimum*

11" W.C.

11" W.C.

Shipping Weight

32 lbs.

34 lbs.

* For purpose of input adjustment

For more information, visit www.desatech.com

111826-05

Image 22
Contents VF-24N-EMU VF-24P-EMU VF-18N-EMU VF-18P-EMU What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Product IdentificationLocal Codes Optional Remote Control AccessoriesProduct Features UnpackingConfined and Unconfined Space Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation and Clearances for VENT-FREE Operation InstallationCheck GAS Type If Not Using Mantel Minimum Noncombustible Material ClearancesFloor Clearances Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Assembly Area of Various Standard Round FluesConnecting to GAS Supply Pressure Testing Heater Gas Connections Pressure Testing gas Supply Piping systemChecking GAS Connections Checking Gas Joints propane/LP only Operating Heater For Your Safety Read Before LightingLighting Instructions Remote Control Operation Manual Lighting ProcedureTo Turn OFF GAS to Appliance Selector Toggle Switch Optional Remote Control Pilot Flame Pattern Inspecting BurnersBurner Flame Pattern Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Troubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement at Specifications VF-18N-EMU VF-24N-EMUTechnical Service Wiring DiagramService Hints Replacement PartsLog sets and mounting plates are ordered as an assembly Illustrated Parts BreakdownVF-24N-EMU Parts List Parts ListAccessories This page Intentionally Left Blank Owners Registration Form Postage Required 111826-05 Warranty Information