Desa VF-24P-EMU, VF-18P-EMU, VF-18N-EMU, VF-24N-EMU installation manual Parts List

Page 26

26

PARTS LIST

VF-24N-PDG, VF-24P-PDG, VF-24N-BTB, VF-24P-BTB, VF-18N-PDG, VF-18P-PDG, VF-18N-BTB, VF-18P-BTB

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instruc- tions listed under Replacement Parts on page 23 of this manual.

KEY

 

 

PART NUMBER FOR

 

DESCRIPTION

QTY

NO.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VF-18N-EMU

VF-18P-EMU

VF-24N-EMU

VF-24P-EMU

 

 

 

 

 

 

 

 

 

 

 

 

1

111808-01

111808-01

111793-01

111793-01

GRATE ASSEMBLY

1

2

 

see table

see table

see table

see table

GTA (Gas Train Assembly)

1

 

 

page 25

page 25

page 25

page 25

 

 

 

3

111835-01

111835-01

111827-01

111827-01

LOG ASSEMBLY

1

4

111803-05

111803-05

111803-02

111803-02

BRACKET-BURNER RIGHT

1

5

111803-04

111803-04

111803-01

111803-01

BRACKET-BURNER LEFT

1

6

111800-01

111800-01

111800-01

111800-01

SCREW

22

7

111817-01

111817-01

111817-01

111817-01

FLEXTUBE 3/8 X 15

1

8

112823-01

112823-01

112823-01

112823-01

BRASS T-FITTING

1

9

111804-04

111804-04

111804-02

111804-02

BURNER, FRONT

1

10

111819-04

111819-05

111819-08

111819-06

ORIFICE, FRONT

1

11

111807-01

111807-02

111807-01

111807-02

VALVE

1

12

111796-01

111796-01

111796-01

111796-01

BRACKET-VALVE

1

13

097159-04

097159-04

097159-04

097159-04

PIEZO IGNITOR

1

14

103784-01

103784-01

103784-01

103784-01

CONTROL KNOB EXT.

1

15

103784-02

103784-02

103784-02

103784-02

CONTROL KNOB EXT.

1

16

099998-01

099998-01

099998-01

099998-01

SWITCH

1

17

112806-01

112806-01

112806-01

112806-01

REMOTE CONTROL ASSY.

1

18

112806-02

112806-02

112806-02

112806-02

BRACKET-REMOTE

1

19

111817-02

111817-02

111817-02

111817-02

FLEXTUBE 3/16 X 6

1

20

111796-02

111796-02

111796-02

111796-02

SHIELD-PILOT

1

21

112376-01

103778-01

112376-01

103778-01

PILOT

1

22

111828-01

111828-01

111828-01

111828-01

COMPRESSION NUT/SLEEVE

1

23

111803-03

------

111803-03

------

AIR SHUTTER, FRONT

1

24

111824-01

111824-01

111824-01

111824-01

COMPRESSION NUT/SLEEVE

2

25

111816-01

111816-01

111816-01

111816-01

SCREW

4

26

111817-04

111817-04

111817-04

111817-04

FLEXTUBE 3/8 X 19

1

27

 

 

 

111819-09

111819-07

ORIFICE, REAR

1

28

112809-04

------

112809-04

------

AIR SHUTTER, REAR

1

29

 

 

 

111804-06

111804-06

BURNER, REAR

1

30

112809-02

112809-02

112809-02

112809-02

BRACKET, REAR RIGHT

1

31

112809-03

112809-03

112809-03

112809-03

BRACKET, REAR LEFT

1

32

111782-01

111782-01

111792-01

111782-01

S CREW, 8-32 X 3/8

2

 

 

 

 

 

 

 

 

 

 

 

 

 

PARTS AVAILABLE NOT SHOWN

 

 

 

 

 

 

 

 

 

 

 

 

 

100563-01

100563-01

100563-01

100563-01

WARNING PLATE

 

1

 

 

112796-01

112796-01

112796-01

112796-01

LIGHTING INSTRUCTION

 

1

 

 

100639-01

100639-01

100639-01

100639-01

CAUTION DECAL

 

1

 

 

GA6060

GA6060

GA6060

GA6060

LAVA ROCK

 

1

 

 

111288-02

111288-02

111288-02

111288-02

GAS LINE FLEX 18

 

1

 

 

112363-01

112363-01

112363-01

112363-01

LOG SCRAP KIT#1

 

1

 

 

112364-01

112364-01

112364-01

112364-01

LOG SCRAP KIT#2

 

1

 

 

112799-01

112799-01

112799-01

112799-01

EMBER FLAKES KIT

 

1

 

 

 

 

 

 

 

 

 

For more information, visit www.desatech.com

111826-05

Image 26
Contents VF-24N-EMU VF-24P-EMU VF-18N-EMU VF-18P-EMU What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Product IdentificationLocal Codes Optional Remote Control AccessoriesProduct Features UnpackingDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationConfined and Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation and Clearances for VENT-FREE Operation If Not Using Mantel Minimum Noncombustible Material ClearancesFloor Clearances Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Assembly Area of Various Standard Round FluesConnecting to GAS Supply Checking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Checking Gas Joints propane/LP only Lighting Instructions For Your Safety Read Before LightingOperating Heater To Turn OFF GAS to Appliance Manual Lighting ProcedureRemote Control Operation Selector Toggle Switch Optional Remote Control Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Logs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement at Specifications VF-18N-EMU VF-24N-EMUTechnical Service Wiring DiagramService Hints Replacement PartsLog sets and mounting plates are ordered as an assembly Illustrated Parts BreakdownVF-24N-EMU Parts List Parts ListAccessories This page Intentionally Left Blank Owners Registration Form Postage Required 111826-05 Warranty Information