Desa VTDMV18NA, VTDMV24PA, VTDMV24NA, VTDMV18PA installation manual Maintenance

Page 15

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Dark orange flame in burner dur-

1.

Not enough air

1.

Check burner(s) for dirt

ing burner combustion

 

 

 

and debris. If found, clean

 

 

 

 

burner(s) (see Cleaning and

 

2.

Gas regulator defective

 

Maintenance, page 12)

 

2.

Replace gas regulator

 

 

 

 

 

Slight smoke or odor during initial

1.

Residues from manufacturing

1.

Problem will stop after a few

operation

 

processes and log curing

 

hours of operation

 

 

 

 

 

Produces a whistling noise when

1.

Turning control knob to HI

1.

Turn control knob to LO

burners are lit

 

position when burners are

 

position and let warm up for

 

 

cold

 

a minute

 

2.

Air is gas line

2.

Operate burners until air is

 

 

 

 

removed from line. Have gas

 

 

 

 

line checked by local natural

 

 

 

 

or propane/LP gas company.

 

3.

Air passageways on heater

3.

Observe minimum installation

 

 

blocked

 

clearances (see page 6)

 

4.

Dirty or partially clogged

4.

Clean burners (see Cleaning

 

 

burner orifice(s)

 

and Maintenance, page 12) or

 

 

 

 

replace burner orifice(s)

White powder residue forming within burner box or on adjacent walls or furniture

1.When heated, vapors from furniture polish, wax, carpet cleaners, etc, turn into white powder residue

1.Heat turned off when using furniture polish, wax, carpet cleaners or ism

114926-01B

www.desatech.com

15

Image 15
Contents VTDMV24NA, VTDMV24PA VTDMV18NA and VTDMV18PA What to do if YOU Smell GASTable of Contents Safety Information High traffic areas Windy or drafty areas Local CodesUnpacking Product FeaturesInstallation Product IdentificationInstallation Installation and ClearancesFlue Opening Specifications Venting Specifications forInstalling Appliance Connecting to GAS SupplyInstallation Items Needed Propane/LP Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig Natural From Gas Meter 5 W.C.** to 10.5 W.C. Pressure KPaPlacement of Loose Embers Pressure Testing Appliance Gas ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Operating Appliance Inspecting Burners Pilot Flame PatternON/OFF Series Model Ghrcb Replacement Parts Cleaning Maintenance Service Hints Technical ServiceObserved Problem Possible Cause Remedy TroubleshootingSee Wiring Diagram, Maintenance, Gas leak. See Warning Statement at topGas leak. See Warning statement at top Specifications AccessoriesWiring Diagram VTDMV24NA, VTDMV24PA VTDMV18NA, VTDMV18PA Illustrated Parts BreakdownParts List Warranty Information Keep this WarrantyLimited Warranty Vented GAS LOG Appliances