Desa REM200T owner manual Theory Operation, Extension Cord Wire Size Requirements, To Start Heater

Page 5

OWNER’S MANUAL

THEORY OF

OPERATION

The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber.

OPERATION

WARNING: Review and un- derstand the warnings in the

Safety Information section, page

2.They are needed to safely op- erate this heater. Follow all local codes when using this heater.

EXTENSION CORD WIRE SIZE REQUIREMENTS

6 to 10 feet long, use 18 AWG rated cord

11 to 100 feet long, use 16 AWG rated cord

101 to 200 feet long, use 14 AWG rated cord

5. Plug extension cord into standard 120

volt/60 hertz, three-hole, grounded out-

The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.

The Ignition System: The electronic ignitor sends voltage to the spark plug. The spark plug ignites the fuel and air mixture.

The Flame-out Control System: This system causes the heater to shut down if the flame goes out.

TO START HEATER

1.Follow all ventilation and safety infor- mation.

2.Fill fuel tank with kerosene or No. 1 fuel oil.

3.Attach fuel cap.

4.Plug power cord of heater into three- prong, grounded extension cord. Exten- sion cord must be at least six feet long.

let. Adjust thermostat to desired setting.

If heater does not start, thermostat set-

ting may be too low. Turn thermostat

knob to higher position to start heater.

If thermostat is in HIGH position and

heater still will not start, push in flame-

out control reset button (see Figure 4).

Note: A cold heater may affect the ther-

mostat setting. This thermostat is a gen-

eral-heating control. It is not intended

for precise temperature control. Adjust

thermostat until heater cycles at the

desired setting.

 

 

 

Motor

Air Pump

Combustion

Spark

Burner

Fan

Air

Intake

Chamber

Plug

Head

 

Filter

 

 

 

Clean

 

 

 

Cool

Heated

 

 

 

Air

Air Out

 

 

 

In

Air

Output

Filter

Fuel

Nozzle

Fuel

Air Line

Electronic

Tank

Filter

To Burner

Ignitor

 

 

Air For Fuel

 

Air For Combustion

Fuel

 

System

 

And Heating

 

 

 

Figure 3 - Cross Section Operational View

TO STOP HEATER

Unplug extension cord from outlet.

TO RESTART HEATER

1.Wait two minutes after stopping heater.

2.Repeat steps under To Start Heater.

Flame-out

Control

Reset

Button

Figure 4 - Flame-out Control Reset Button

106068

5

Image 5
Contents Portable Forced AIR Heater Fueling Safety InformationUnpacking Product IdentificationFuels AssemblyVentilation Tools NeededTheory Operation Extension Cord Wire Size RequirementsTo Start Heater To Stop HeaterSchedule Preventative MaintenanceStoring TRANSPORTING, or Shipping Troubleshooting Upper Shell Removal Service ProceduresFAN AIR OUTPUT, AIR INTAKE, and Lint FiltersFuel Valve Pump Pressure AdjustmentFuel Filter Nozzle Spark PlugPump Rotor REM200T Illustrated Parts BreakdownDesired part Parts ListMaintenance Kits SpecificationsTechnical Service Wheels and Handle Parts ListAccessories Replacement Parts Wiring DiagramInternational Warranty ServiceRepair Service

REM200T specifications

The Desa REM200T is a sophisticated and versatile heating solution designed to provide efficient warmth for various spaces. This model stands out due to its blend of modern technology, user-friendly features, and reliable performance, making it an excellent choice for homeowners and businesses alike.

One of the main features of the Desa REM200T is its exceptional heat output, which can effectively warm rooms of various sizes. With an output capacity of up to 200,000 BTUs, this unit can easily handle larger spaces, ensuring consistent comfort during cold weather. The REM200T is fueled by natural gas or propane, providing users with flexible options depending on their energy preferences and availability.

This heating solution incorporates advanced technologies such as electronic ignition, which ensures reliable start-up and minimizes the need for manual ignitions. The inclusion of a high-efficiency design helps maximize heat output while reducing energy consumption, ultimately lowering utility bills and lessening environmental impact.

Safety is a paramount concern in any heating appliance, and the Desa REM200T does not disappoint in this regard. It comes equipped with multiple safety features including an automatic shut-off system that activates in the event of an overheating situation, as well as a durable construction designed to withstand wear and tear. The unit also features a built-in thermostat, allowing users to maintain their desired temperature effortlessly.

Another notable characteristic of the Desa REM200T is its aesthetically pleasing design. The unit boasts a sleek exterior that can seamlessly fit into various decor styles, making it a practical yet stylish addition to any space. Its compact dimensions ensure that it can be easily installed in a variety of locations, including homes, garages, and workshops.

Ease of use is further enhanced by the user-friendly control panel, which provides straightforward operation and programming options. Whether setting the timer or adjusting the heat output, navigating the controls is simple and intuitive.

In summary, the Desa REM200T offers a powerful and efficient heating solution with a range of features designed for safety, convenience, and performance. Its adaptability to different fuel types, impressive heat output, and modern technologies make it an ideal choice for those seeking reliable warmth in any environment.