Desa RFP30TA Inspecting Burner, Thermostat Control Operation, Manual Lighting Procedure

Page 15

OWNER’S MANUAL

OPERATING

HEATER

Continued

THERMOSTAT

CONTROL

OPERATION

The thermostatic control used on this heater differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or de- creases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature.

The control knob can be set to any heat level between HI and LO.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation loca- tion, room size, open air temperatures, etc.). Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 2, page 4).

2.Follow steps 1 through 5 under Light- ing Instructions, page 14.

3.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instruc- tions, page 14.

5.Replace front panel.

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 24 shows a correct pilot flame pat- tern. Figure 25 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 25

turn heater off (see To Turn Off Gas to Appliance, page 14)

seeTroubleshooting, pages 17 through 19

Pilot Burner

Thermocouple

Figure 24 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 25 - Incorrect Pilot Flame Pattern

BURNER FLAME PATTERN

Figure 26 shows a correct burner flame pattern. Figure 27 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than one inch above the log.

Note: When using the heater the first time, the flame will be yellow for approximately one hour until the log cures.

WARNING: If yellow tipping occurs, your heater could pro- duce increased levels of carbon monoxide. If burner flame pattern shows yellow tipping, follow in- structions at bottom of this page.

NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the heater and burn causing brief patches of orange flame.

If burner flame pattern is incorrect, as shown in Figure 27

turn heater off (see To Turn Off Gas to Appliance, page 14)

seeTroubleshooting, pages 17 through 19

Top of Flame Even

With Top of Log

Figure 26 - Correct Burner Flame Pattern at High Position

Yellow Tipping

Figure 27 - Incorrect Burner Flame Pattern at High Position

107100

15

For more information, visit www.desatech.com

Image 15
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GAS15,000 to 30,000 Btu/Hr With Thermostat Local Codes Safety InformationUnpacking AssemblyProduct Features Product IdentificationAssembling and Attaching Brass Trim Attaching Brass Front Trim to Front PanelConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation Items Locating HeaterCheck GAS Type Installation Options Thermostat Sensing BulbMounting Heater to Wall Placing Heater On Mounting Bracket Installing Bottom Mounting ScrewsMounting Heater on Optional Hearth Base Attaching Mounting Bracket to WallSecuring Hearth Base to Floor See Instructions Included With Mantel Kit Assembling MantelMounting Heater to Optional Hearth Base External Regulator with Vent Pointing Down Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections To Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Heater Lighting InstructionsPilot Flame Pattern Manual Lighting ProcedureInspecting Burner Thermostat Control OperationCleaning and Maintenance Replacement PartsService Hints Observed Problem Possible Cause Remedy TroubleshootingObserved Problem Possible Cause Gas leak. See Warning statement at Specifications Technical ServiceParts Centrals Accessories RFP30TA Illustrated Parts BreakdownKEY RFP30TA Description QTY Parts ListModel Serial No Date Purchased Warranty Information

RFP30TA specifications

The Desa RFP30TA is a standout heating solution designed for residential and light commercial spaces. With a powerful output and a variety of features, this gas-fired heater is built to provide efficient warmth while ensuring safety and convenience for users.

One of the main features of the Desa RFP30TA is its impressive heating capacity. With an output of up to 30,000 BTUs, it is capable of warming spaces of approximately 1,000 square feet, making it suitable for larger rooms or open areas. This makes it an excellent choice for basements, workshops, or other spaces that require effective heating during colder months.

The heater is designed with efficiency in mind. It boasts a high Annual Fuel Utilization Efficiency (AFUE) rating, which translates to lower energy bills and reduced greenhouse gas emissions. Its innovative design ensures that more of the fuel is converted into usable heat, which is not only economical for users but also beneficial for the environment.

As for technology, the Desa RFP30TA incorporates advanced safety features that prioritize user protection. The unit is equipped with a built-in safety shut-off system that automatically turns off the heater if it detects any irregularities in operation. Additionally, it utilizes a reliable thermocouple that monitors flame presence, ensuring that the heater operates safely at all times.

Another characteristic that sets the Desa RFP30TA apart is its versatility in installation. The heater comes with options for both vented and unvented installations, allowing users to choose the best setup for their specific needs. This flexibility means that the unit can be installed in a variety of locations, whether it’s vented to the outdoors or designed for indoor use without the need for a flue.

Furthermore, the Desa RFP30TA is designed with user-friendly controls. The adjustable thermostat allows for precise temperature management, enabling users to maintain their desired comfort level. This feature, combined with the unit's robust build quality, makes it a reliable option for long-term use.

In summary, the Desa RFP30TA is an efficient and powerful heating solution that combines modern technology with user-centric design. With its impressive output, safety features, installation flexibility, and user-friendly controls, it stands as a top choice for those looking for an effective heating solution for their spaces.