Desa RFP30TA installation manual Safety Information, Local Codes

Page 2

VENT-FREE PROPANE/LP HEATER

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nau- sea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or ane- mia, those under the influence of alcohol, and those at high altitudes.

Propane/LP Gas: Propane/LP gas is odor- less. An odor-making agent is added to pro- pane/LP gas. The odor helps you detect a propane/LP gas leak. However, the odor added to propane/LP gas can fade. Propane/LP gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not allow fans to blow directly into the heater. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not approved for use with this heater.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Surface of heater becomes very hot when running heater. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shut- down. Allow surfaces to cool be- fore touching.

Carefully supervise young chil- dren when they are in same room with heater.

Make sure screen is in place be- fore running heater.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This heater shall not be installed in a bedroom or bathroom.

5.This heater needs fresh, outside air ven- tilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 5 through 7.

6.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.

7.To prevent the creation of soot, follow the instructions in Cleaning and Main- tenance, page 16.

8.Before using furniture polish, wax, car- pet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white pow- der residue within burner box or on adjacent walls or furniture.

9.Do not run heater

where flammable liquids or vapors are used or stored.

under dusty conditions.

10.Do not use heater if any part has been under water. Immediately call a quali- fied service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

11.Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.

12.Operating heater above elevations of 4,500 feet may cause pilot outage.

13.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.1, also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

For more information, visit www.desatech.com

2

107100

Image 2
Contents 15,000 to 30,000 Btu/Hr With Thermostat OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Safety Information Local CodesProduct Identification AssemblyProduct Features UnpackingAttaching Brass Front Trim to Front Panel Assembling and Attaching Brass TrimUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Items Locating Heater Mounting Heater to Wall Installation OptionsThermostat Sensing Bulb Attaching Mounting Bracket to Wall Installing Bottom Mounting ScrewsMounting Heater on Optional Hearth Base Placing Heater On Mounting BracketMounting Heater to Optional Hearth Base Securing Hearth Base to FloorSee Instructions Included With Mantel Kit Assembling Mantel Connecting to GAS Supply External Regulator with Vent Pointing DownChecking GAS Connections Pressure Testing Heater Gas ConnectionsPressure Testing Gas Supply Piping System Lighting Instructions For Your Safety Read Before LightingOperating Heater To Turn OFF GAS To ApplianceThermostat Control Operation Manual Lighting ProcedureInspecting Burner Pilot Flame PatternService Hints Cleaning and MaintenanceReplacement Parts Troubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause Gas leak. See Warning statement at Parts Centrals SpecificationsTechnical Service Accessories Illustrated Parts Breakdown RFP30TAParts List KEY RFP30TA Description QTYWarranty Information Model Serial No Date Purchased

RFP30TA specifications

The Desa RFP30TA is a standout heating solution designed for residential and light commercial spaces. With a powerful output and a variety of features, this gas-fired heater is built to provide efficient warmth while ensuring safety and convenience for users.

One of the main features of the Desa RFP30TA is its impressive heating capacity. With an output of up to 30,000 BTUs, it is capable of warming spaces of approximately 1,000 square feet, making it suitable for larger rooms or open areas. This makes it an excellent choice for basements, workshops, or other spaces that require effective heating during colder months.

The heater is designed with efficiency in mind. It boasts a high Annual Fuel Utilization Efficiency (AFUE) rating, which translates to lower energy bills and reduced greenhouse gas emissions. Its innovative design ensures that more of the fuel is converted into usable heat, which is not only economical for users but also beneficial for the environment.

As for technology, the Desa RFP30TA incorporates advanced safety features that prioritize user protection. The unit is equipped with a built-in safety shut-off system that automatically turns off the heater if it detects any irregularities in operation. Additionally, it utilizes a reliable thermocouple that monitors flame presence, ensuring that the heater operates safely at all times.

Another characteristic that sets the Desa RFP30TA apart is its versatility in installation. The heater comes with options for both vented and unvented installations, allowing users to choose the best setup for their specific needs. This flexibility means that the unit can be installed in a variety of locations, whether it’s vented to the outdoors or designed for indoor use without the need for a flue.

Furthermore, the Desa RFP30TA is designed with user-friendly controls. The adjustable thermostat allows for precise temperature management, enabling users to maintain their desired comfort level. This feature, combined with the unit's robust build quality, makes it a reliable option for long-term use.

In summary, the Desa RFP30TA is an efficient and powerful heating solution that combines modern technology with user-centric design. With its impressive output, safety features, installation flexibility, and user-friendly controls, it stands as a top choice for those looking for an effective heating solution for their spaces.