Desa RFP30TA Operating Heater, For Your Safety Read Before Lighting, Lighting Instructions

Page 14

VENT-FREE PROPANE/LP HEATER

OPERATING

HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, column 1.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation, column 1. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise

C-clockwiseto the PILOT position. Press in control knob for five (5) seconds (see Figure 22).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 17 through 19. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 15.

Ignitor Button

Control Knob

 

LO

 

PILOT

 

OFF

 

HI

IGNITOR

 

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

8.Turn control knob counterclockwise

C-clockwiseto desired heating level. The main burner should light. Set con- trol knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

Thermocouple

Ignitor Electrode

Pilot Burner

Figure 23 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise Clockwise to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise Clockwise to the PILOT position.

gnitor Button

Figure 22 - Control Knob In The OFF Position

For more information, visit www.desatech.com

14

107100

Image 14
Contents 15,000 to 30,000 Btu/Hr With Thermostat OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Safety Information Local CodesProduct Identification AssemblyProduct Features UnpackingAttaching Brass Front Trim to Front Panel Assembling and Attaching Brass TrimUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Items Locating Heater Mounting Heater to Wall Installation OptionsThermostat Sensing Bulb Attaching Mounting Bracket to Wall Installing Bottom Mounting ScrewsMounting Heater on Optional Hearth Base Placing Heater On Mounting BracketMounting Heater to Optional Hearth Base Securing Hearth Base to FloorSee Instructions Included With Mantel Kit Assembling Mantel Connecting to GAS Supply External Regulator with Vent Pointing DownChecking GAS Connections Pressure Testing Heater Gas ConnectionsPressure Testing Gas Supply Piping System Lighting Instructions For Your Safety Read Before LightingOperating Heater To Turn OFF GAS To ApplianceThermostat Control Operation Manual Lighting ProcedureInspecting Burner Pilot Flame PatternService Hints Cleaning and MaintenanceReplacement Parts Troubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause Gas leak. See Warning statement at Parts Centrals SpecificationsTechnical Service Accessories Illustrated Parts Breakdown RFP30TAParts List KEY RFP30TA Description QTYWarranty Information Model Serial No Date Purchased

RFP30TA specifications

The Desa RFP30TA is a standout heating solution designed for residential and light commercial spaces. With a powerful output and a variety of features, this gas-fired heater is built to provide efficient warmth while ensuring safety and convenience for users.

One of the main features of the Desa RFP30TA is its impressive heating capacity. With an output of up to 30,000 BTUs, it is capable of warming spaces of approximately 1,000 square feet, making it suitable for larger rooms or open areas. This makes it an excellent choice for basements, workshops, or other spaces that require effective heating during colder months.

The heater is designed with efficiency in mind. It boasts a high Annual Fuel Utilization Efficiency (AFUE) rating, which translates to lower energy bills and reduced greenhouse gas emissions. Its innovative design ensures that more of the fuel is converted into usable heat, which is not only economical for users but also beneficial for the environment.

As for technology, the Desa RFP30TA incorporates advanced safety features that prioritize user protection. The unit is equipped with a built-in safety shut-off system that automatically turns off the heater if it detects any irregularities in operation. Additionally, it utilizes a reliable thermocouple that monitors flame presence, ensuring that the heater operates safely at all times.

Another characteristic that sets the Desa RFP30TA apart is its versatility in installation. The heater comes with options for both vented and unvented installations, allowing users to choose the best setup for their specific needs. This flexibility means that the unit can be installed in a variety of locations, whether it’s vented to the outdoors or designed for indoor use without the need for a flue.

Furthermore, the Desa RFP30TA is designed with user-friendly controls. The adjustable thermostat allows for precise temperature management, enabling users to maintain their desired comfort level. This feature, combined with the unit's robust build quality, makes it a reliable option for long-term use.

In summary, the Desa RFP30TA is an efficient and powerful heating solution that combines modern technology with user-centric design. With its impressive output, safety features, installation flexibility, and user-friendly controls, it stands as a top choice for those looking for an effective heating solution for their spaces.