OPERATING HEATER (REMOTE-READY MODELS)

Lighting Instructions (Cont.)

To Turn Off Gas To Appliance

Manual Lighting Procedure

OPERATING HEATER

Continued

7.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8.

9.Slightly push in and turn control knob counterclockwise to the ON position.

10.Wait one minute and switch selector switch to the ON posi- tion to light burner. Note: AUTO is only functional when using GWMT1 or GWMS2 optional accessories.

11.To light the front/rear burners, push in and turn rear burner

control knob counterclockwise to the ON position.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

WARNING: Make sure the selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on automatically with selector switch in the ON position.

Control Knob

Rear Burner

Control Knob

 

 

ILOT

O

 

 

P

 

 

F

N

 

 

F

 

AUTO

OFF

O

 

ON

 

Selector

Ignitor Button

 

Switch

 

Figure 32 - Control Knobs and Ignitor Button Locations (Shown as Supplied, No Remote Control Operation)

Pilot Burner

Ignitor

Ignitor Electrode

 

Thermocouple

Thermocouple

Electrode

Pilot Burner

 

 

 

Figure 33 - Pilot (Propane/LP) Figure 34 - Pilot (Natural)

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2.Turn rear burner control knob clockwise to the OFF position.

3a. Set selector switch in the OFF position.

3b. If Using Optional Hand-Held Remote: Set selector switch in the OFF position to prevent draining battery.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

1.Turn control knob clockwise to the PILOT position.

2.Turn rear burner control knob clockwise to the OFF position.

3.Use remote control manual OFF button.

4.Set selector switch in the OFF position.

MANUAL LIGHTING PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, page 20.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 12, Lighting Instructions, column 1.

For..com

110021-01C

Image 20
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Optional Remote Control Accessories Product IdentificationLocal Codes UnpackingProduct Features AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation and Clearances for VENT-FREE Operation Minimum Noncombustible Material Clearances See Between 8Determining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Remote-Ready Models OnlyConnecting to GAS Supply Attaching Extension Plates to Base Assembly 30 Model OnlyExternal Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Installing Logs Installing Log #1 Ember Bed Model CSG3924NR ShownInstalling Log #2 Right and Log #3 Left Model VRL30NR Shown Attaching Grate to Base Assembly Operating HeaterAdding Lava Rock Lighting InstructionsShutting Off Burners Only pilot stays lit To Turn OFF GAS to ApplianceShutting Off Heater Thermostat Control Operation Manual Lighting ProcedureREMOTE-READY Models For Your Safety Read Before Lighting Control Knob Rear Burner Optional Remote Operation Thermostat Control OperationGhrc Series Operation Ghrcta Series OperationBurner Flame Patterns Inspecting BurnersPilot Flame Pattern Logs Cleaning MaintenanceCleaning Burner Injector Holders and Pilot AIR Inlet Holes Troubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement Optional Positioning of Thermostat Sensing Bulb Important Do not crimp capillarySpecifications Wiring DiagramService Hints Technical ServiceIllustrated Parts Breakdown For more Visit www ComTHERMOSTAT-CONTROLLED VRL24NT, VRL24PT VRL30NT, VRL30PT Parts List THERMOSTAT-CONTROLLEDREMOTE-READY VRL24NR, VRL24PR VRL30NR, VRL30PR CSG3924NR, CSG3924PR CTB3924NR, CTB3924PRREMOTE-READY Replacement Parts AccessoriesOwners Registration Form Postage Required 110021-01C Not a UPC

CSG3924NR, CTB3924NR, VRL24PR, VRL30NR, RL24NR specifications

Desa VRL30NR, CSG3924PR, RL24NR, CSG3924PT, and CTB3924NT are advanced heating units developed by Desa, a brand recognized for its innovation in heating technologies. These models cater to a variety of consumer needs, offering efficient, reliable, and cost-effective heating solutions for residential and commercial applications.

The Desa VRL30NR is a powerful model known for its exceptional performance and efficiency. It features an intuitive digital thermostat for precise temperature control, ensuring optimal comfort. The unit is designed with an advanced airflow system that maximizes heat distribution throughout the space, making it ideal for larger rooms or open-concept spaces. The VRL30NR is also equipped with safety features such as an automatic shut-off mechanism that activates in case of overheating or tip-over, providing added peace of mind.

In contrast, the CSG3924PR and CSG3924PT models offer versatility with a sleek design and robust functionality. Both models come with an adjustable flame height feature, allowing users to customize their heating experience based on preference and room size. These units are designed for easy installation and operation, often incorporating wall-mounted options to save floor space. The incorporation of energy-efficient technologies ensures that they consume less power while still delivering powerful heating output, making them an environmentally friendly choice.

The RL24NR model stands out with its compact design, making it suitable for smaller spaces. This model prioritizes aesthetics without compromising on performance. It is equipped with a quiet operation mode, making it perfect for bedrooms or offices where noise levels need to be minimal. The RL24NR also boasts a quick heat-up time, providing instant warmth when needed.

Lastly, the CTB3924NT model offers the best in technology and features. It includes a built-in air purification system that not only heats but also improves indoor air quality. This model is equipped with Wi-Fi connectivity, allowing users to control their heating remotely via a smartphone app. Its smart technology integrates with home automation systems, enhancing convenience and user experience.

Overall, each of these Desa models provides reliable heating solutions tailored to diverse needs and spaces. Their combined focus on efficiency, safety, and user-friendly features makes them standout options in the competitive heating market.