Desa CSG3924NR, RL24NR, CTB3924NT, CTB3924NR Illustrated Parts Breakdown, For more Visit www Com

Page 29

ILLUSTRATED PARTS BREAKDOWN

Logs

29

ILLUSTRATED PARTS BREAKDOWN

LOGS

7

7

6

 

6

4

5

5

4

3

2

3

2

Log Set for Models: VRL24NT, VRL24PT, VRL24NR, VRL24PR, VRL30NT, VRL30PT, VRL30NR, VRL30PR

Log Set for Models:

CSG3924NT, CSG3924PT, CSG3924NR, CSG3924PR, CTB3924NT, CTB3924PT, CTB3924NR, and CTB3924PR

 

PART NUMBER FOR

 

 

 

 

 

CSG3924NT

 

 

 

 

 

CSG3924PT

 

 

 

 

 

CSG3924NR

 

 

 

 

 

CSG3924PR

 

 

 

VRL24NT

VRL30NT

CTB3924NT

 

 

 

VRL24PT

VRL30PT

CTB3924PT

 

 

KEY

VRL24NR

VRL30NR

CTB3924NR

 

 

NO.

VRL24PR

VRL30PR

CTB3924PR

DESCRIPTION

QTY.

 

 

 

 

 

 

1

110020-01

110020-02

110020-03

Log Set

1

2

110103-01

110103-01

110103-01

Log Ember Bed

1

3

110105-01

110106-01

110107-01

Log, Right Front

1

4

110105-02

110106-02

110107-02

Log, Left Front

1

5

110105-03

110106-03

110107-03

Log, Back

1

6

110105-04

110106-04

110107-04

Log, Right Crossover

1

7

110104-01

110104-01

110104-01

Log, Left Crossover

1

 

 

 

 

 

 

For more

visit www.

.com

110021-01C

Image 29
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsSafety Information Product Identification Optional Remote Control AccessoriesLocal Codes UnpackingAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation and Clearances for VENT-FREE Operation See Between 8 Minimum Noncombustible Material ClearancesMantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Remote-Ready Models OnlyAttaching Extension Plates to Base Assembly 30 Model Only Connecting to GAS SupplyExternal Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Installing Log #1 Ember Bed Model CSG3924NR Shown Installing LogsInstalling Log #2 Right and Log #3 Left Model VRL30NR Shown Operating Heater Attaching Grate to Base AssemblyAdding Lava Rock Lighting InstructionsShutting Off Burners Only pilot stays lit To Turn OFF GAS to ApplianceShutting Off Heater Thermostat Control Operation Manual Lighting ProcedureREMOTE-READY Models For Your Safety Read Before Lighting Control Knob Rear Burner Thermostat Control Operation Optional Remote OperationGhrc Series Operation Ghrcta Series OperationBurner Flame Patterns Inspecting BurnersPilot Flame Pattern Logs Cleaning MaintenanceCleaning Burner Injector Holders and Pilot AIR Inlet Holes Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement Important Do not crimp capillary Optional Positioning of Thermostat Sensing BulbWiring Diagram SpecificationsService Hints Technical ServiceFor more Visit www Com Illustrated Parts BreakdownTHERMOSTAT-CONTROLLED VRL24NT, VRL24PT VRL30NT, VRL30PT THERMOSTAT-CONTROLLED Parts ListCSG3924NR, CSG3924PR CTB3924NR, CTB3924PR REMOTE-READY VRL24NR, VRL24PR VRL30NR, VRL30PRREMOTE-READY Accessories Replacement PartsOwners Registration Form Postage Required 110021-01C Not a UPC

CSG3924NR, CTB3924NR, VRL24PR, VRL30NR, RL24NR specifications

Desa VRL30NR, CSG3924PR, RL24NR, CSG3924PT, and CTB3924NT are advanced heating units developed by Desa, a brand recognized for its innovation in heating technologies. These models cater to a variety of consumer needs, offering efficient, reliable, and cost-effective heating solutions for residential and commercial applications.

The Desa VRL30NR is a powerful model known for its exceptional performance and efficiency. It features an intuitive digital thermostat for precise temperature control, ensuring optimal comfort. The unit is designed with an advanced airflow system that maximizes heat distribution throughout the space, making it ideal for larger rooms or open-concept spaces. The VRL30NR is also equipped with safety features such as an automatic shut-off mechanism that activates in case of overheating or tip-over, providing added peace of mind.

In contrast, the CSG3924PR and CSG3924PT models offer versatility with a sleek design and robust functionality. Both models come with an adjustable flame height feature, allowing users to customize their heating experience based on preference and room size. These units are designed for easy installation and operation, often incorporating wall-mounted options to save floor space. The incorporation of energy-efficient technologies ensures that they consume less power while still delivering powerful heating output, making them an environmentally friendly choice.

The RL24NR model stands out with its compact design, making it suitable for smaller spaces. This model prioritizes aesthetics without compromising on performance. It is equipped with a quiet operation mode, making it perfect for bedrooms or offices where noise levels need to be minimal. The RL24NR also boasts a quick heat-up time, providing instant warmth when needed.

Lastly, the CTB3924NT model offers the best in technology and features. It includes a built-in air purification system that not only heats but also improves indoor air quality. This model is equipped with Wi-Fi connectivity, allowing users to control their heating remotely via a smartphone app. Its smart technology integrates with home automation systems, enhancing convenience and user experience.

Overall, each of these Desa models provides reliable heating solutions tailored to diverse needs and spaces. Their combined focus on efficiency, safety, and user-friendly features makes them standout options in the competitive heating market.