Desa B115T, REM115T, R115T owner manual Safety Information, Unpacking, Fueling

Page 2

115,000 Btu/Hr H.S.I. Series

PORTABLE FORCED AIR HEATER

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this Owner’s Manual carefully and completely before trying to assemble, oper- ate, or service this heater. Improper use of this heater can cause seri- ous injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include preg- nant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, al- cohol, or other highly flammable fuels.

Fueling

a)Personnel involved with fueling shall be qualified and thoroughly familiar with the manufacturer’s instructions and applicable federal, state, and lo- cal regulations regarding the safe fu-

eling of heating units.

b)Only the type of fuel specified on the heater’s data plate shall be used.

c)All flame, including the pilot light, if any, shall be extinguished and the heater al-

lowed to cool, prior to fueling. d)During fueling, all fuel lines and fuel-

line connections shall be inspected for leaks. Any leaks shall be repaired prior to returning the heater to service.

e)At no time shall more than one day’s supply of heater fuel be stored inside a building in the vicinity of the heater. Bulk fuel storage shall be outside the structure.

f)All fuel storage shall be located a minimum of 25 feet from heaters, torches, welding equipment, and similar sources of ignition (excep- tion: the fuel reservoir integral with

the heater unit).

g)Whenever possible, fuel storage shall be confined to areas where floor pen- etrations do not permit fuel to drip onto or be ignited by a fire at lower elevation.

h)Fuel storage shall be in accordance with the federal, state, or local author- ity having jurisdiction.

Never use heater where gasoline, paint thinner, or other highly flammable va- pors are present.

Follow all local ordinances and codes when using heater.

Heaters used in the vicinity of tarpau- lins, canvas, or similar enclosure mate- rials shall be located a safe distance from such materials. The recommended minimum safe distance is 10 feet. It is further recommended that these enclo- sure materials be of a fire retardant na- ture. These enclosure materials shall be securely fastened to prevent them from igniting or from upsetting the heater due to wind action.

Use only in well-vented areas. Before using heater, provide at least a three- square-foot opening of fresh, outside air for each 100,000 Btu/Hr of rating. This heater produces carbon monoxide, which is listed by the State of Califor- nia as a reproductive toxin under Propo- sition 65.

Use only in places free of flammable vapors or high dust content.

Use only the electrical voltage and fre- quency specified on model plate.

Use only a three-prong, grounded ex- tension cord.

Minimum heater clearances from com- bustibles:

Outlet: 8 Ft. Sides: 4 Ft.

Top: 4 Ft. Rear: 4 Ft.

Locate heater on a stable and level sur- face if heater is hot or running or a fire may occur.

When moving or storing heater, keep heater in a level position or fuel spill- age may occur.

Keep children and animals away from heater.

Unplug heater when not in use.

When used with thermostat, heater may start anytime.

Never use heater in living or sleeping areas.

Never block air inlet (rear) or air outlet (front) of heater.

Never move, handle, refuel, or service a hot, operating, or plugged-in heater.

Never attach duct work to front or rear of heater.

Warning to New York City Residents For Use Only At Construction Sites in accordance with applicable NYC codes under NYCFD certificate of approval #4803, #4899, #4908, #4909, or #4934.

UNPACKING

1.Remove all packing items applied to heater for shipment.

2.Remove all items from carton.

3.Check items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

2

104193

Image 2
Contents Portable Forced AIR Heater With BUILT-IN ThermostatFueling Safety InformationUnpacking Tools Needed AssemblyProduct Identification Ventilation FuelsTheory Operation Schedule Preventative MaintenanceStoring TRANSPORTING, or Shipping Troubleshooting Upper Shell Removal Service ProceduresPump Pressure Adjustment FANReplace combustion chamber Fuel FilterIgnitor Nozzle Assembly Fuel and AIR Line Replacement Proper RoutingIgnition Control Assembly Pump RotorWiring Diagram Technical Service SpecificationsIllustrated Parts Breakdown REM115TParts List KEY Part Number Description QTYWheels and Handle Parts List Parts Available not ShownReplacement Parts AccessoriesWarranty and Repair Service

B115T, R115T, REM115T specifications

Desa R115T, B115T, and REM115T are models of advanced heating and cooling systems designed to provide optimal performance and efficiency in climate control. These systems have been engineered to meet the diverse needs of both residential and commercial spaces, ensuring comfort regardless of external weather conditions.

The Desa R115T is known for its robustness and reliability. Featuring a powerful heating component, it employs a high-efficiency burner that maximizes heat output while minimizing fuel consumption. The unit integrates state-of-the-art digital controls, allowing for precise temperature settings and scheduling. Key features include a quick warm-up time, quiet operation, and a durable construction that ensures longevity, making it suitable for various applications.

On the other hand, the Desa B115T focuses on versatility and user-friendliness. This model features a dual fuel capability, allowing it to operate on both propane and natural gas, providing flexibility based on availability and preference. Its advanced thermostat offers smart capabilities, enabling remote access via smartphone applications. The B115T’s sleek design and compact size make it an ideal choice for urban environments where space is limited.

The REM115T is another impressive option, primarily distinguished by its eco-friendly design. This model utilizes advanced heat pump technology that extracts heat from the surrounding air, significantly reducing carbon emissions. It is equipped with a variable-speed compressor that adjusts to the heating and cooling demands, providing energy efficiency that can lead to substantial savings on utility bills. The REM115T also includes a built-in air purification system, improving indoor air quality by reducing allergens and pollutants.

All three models boast advanced insulation to enhance their energy efficiency ratings, contributing to lower operational costs. They are equipped with user-friendly interfaces, allowing for easy monitoring and adjustment of settings. Furthermore, their compatibility with smart home systems makes them a modern solution for environmentally conscious users seeking automated comfort.

Overall, Desa R115T, B115T, and REM115T are exemplary models of heating and cooling technology, each offering unique features and capabilities tailored to meet diverse needs while ensuring efficient and reliable climate control. With their cutting-edge technologies, these systems exemplify the future of home and commercial heating solutions.