Desa B115T, REM115T, R115T Storing TRANSPORTING, or Shipping, Preventative Maintenance, Schedule

Page 5

OWNER’S MANUAL

OPERATION

WARNING: Review and un- derstand the warnings in the Safety Information section, page

2.They are needed to safely oper- ate this heater. Follow all local codes when using this heater.

TO START HEATER

1.

Follow all ventilation and safety infor-

 

mation.

2.

Fill fuel tank with kerosene or No. 1

 

fuel oil.

3.

Attach fuel cap.

4.

Turn thermostat knob clockwise to the

 

HIGH position.

5.

Plug power cord of heater into three-

STORING,

TRANSPORTING, OR SHIPPING

Note: If shipping, transport companies re- quire fuel tanks to be empty.

1.Drain fuel tank.

Note: This model has a drain plug on underside of fuel tank. Remove drain plug to drain all fuel. Be sure all fuel is removed.

2.Replace drain plug.

3.If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank, stir, and drain again. This will prevent excess debris from clogging filters dur- ing future use.

4.Replace fuel cap and drain plug. Prop- erly dispose of old and dirty fuel. Check with local automotive service stations that recycle oil.

5.If storing, store heater in dry place. Make sure storage place is free of dust and corrosive fumes.

IMPORTANT: Do not store kerosene over summer months for use during next heating season. Using old fuel could damage heater.

prong, grounded extension cord. Exten-

sion cord must be at least six feet long.

Extension Cord Wire Size

Requirements

• 6 to 10 feet long, use 18AWG rated cord

• 11 to 100 feet long, use 16 AWG rated

cord

PREVENTATIVE

WARNING: Never service heater while

MAINTENANCE

it is plugged in, operating, or hot. Severe

SCHEDULE

burns and electrical shock can occur.

 

 

Item

How Often

How To

 

 

 

• 101 to 200 feet long, use 14 AWG

rated cord

6. Plug extension cord into standard 120

volt/60 hertz, three-hole, grounded out-

let. Note: Ignitor will preheat for five

seconds then heater will start.

7. Adjust thermostat knob to the desired set-

ting. Note: A cold heater may affect the

thermostat setting. Further adjustment

may be needed until the heater cycles at

Fuel tank

Air output and lint filters

Air intake filter

Flush every 150-200 hours of opera- tion or as needed

Replace every 500 hours of operation or once a year

Wash and dry with soap an water every 500 hours of operation or replace as needed

See Storing, Transporting, or Shipping, above

See Air Output, Air Intake, and Lint Filters, page 7

See Air Output, Air Intake, and Lint Filters, page 7

the desired setting. This thermostat is a

general-heating control. It is not intended

for precise temperature control.

Fuel filter

Clean twice a heating season or re- See Fuel Filter, page 8

 

place as needed

Ignitor

No maintenance required

TO STOP HEATER

Unplug extension cord from outlet.

TO RESET HEATER

1.Unplug extension cord from outlet and wait 10 seconds (two minutes if heater has been running).

2.Turn thermostat knob clockwise to the HIGH position.

3.Plug extension cord into standard 120 volt/ 60 hertz, three-hole, grounded outlet. Note: Ignitor will preheat for five sec- onds then heater will start.

4.Adjust thermostat knob to the desired setting.

Fan blades

Clean each season or as needed

See Fan, page 7

Motor

Not required/permanently lubricated

 

104193

5

Image 5
Contents With BUILT-IN Thermostat Portable Forced AIR HeaterFueling Safety InformationUnpacking Tools Needed AssemblyProduct Identification Ventilation FuelsTheory Operation Schedule Preventative MaintenanceStoring TRANSPORTING, or Shipping Troubleshooting Pump Pressure Adjustment Service ProceduresUpper Shell Removal FANReplace combustion chamber Fuel FilterIgnitor Fuel and AIR Line Replacement Proper Routing Nozzle AssemblyPump Rotor Ignition Control AssemblySpecifications Wiring Diagram Technical ServiceREM115T Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListParts Available not Shown Wheels and Handle Parts ListAccessories Replacement PartsWarranty and Repair Service

B115T, R115T, REM115T specifications

Desa R115T, B115T, and REM115T are models of advanced heating and cooling systems designed to provide optimal performance and efficiency in climate control. These systems have been engineered to meet the diverse needs of both residential and commercial spaces, ensuring comfort regardless of external weather conditions.

The Desa R115T is known for its robustness and reliability. Featuring a powerful heating component, it employs a high-efficiency burner that maximizes heat output while minimizing fuel consumption. The unit integrates state-of-the-art digital controls, allowing for precise temperature settings and scheduling. Key features include a quick warm-up time, quiet operation, and a durable construction that ensures longevity, making it suitable for various applications.

On the other hand, the Desa B115T focuses on versatility and user-friendliness. This model features a dual fuel capability, allowing it to operate on both propane and natural gas, providing flexibility based on availability and preference. Its advanced thermostat offers smart capabilities, enabling remote access via smartphone applications. The B115T’s sleek design and compact size make it an ideal choice for urban environments where space is limited.

The REM115T is another impressive option, primarily distinguished by its eco-friendly design. This model utilizes advanced heat pump technology that extracts heat from the surrounding air, significantly reducing carbon emissions. It is equipped with a variable-speed compressor that adjusts to the heating and cooling demands, providing energy efficiency that can lead to substantial savings on utility bills. The REM115T also includes a built-in air purification system, improving indoor air quality by reducing allergens and pollutants.

All three models boast advanced insulation to enhance their energy efficiency ratings, contributing to lower operational costs. They are equipped with user-friendly interfaces, allowing for easy monitoring and adjustment of settings. Furthermore, their compatibility with smart home systems makes them a modern solution for environmentally conscious users seeking automated comfort.

Overall, Desa R115T, B115T, and REM115T are exemplary models of heating and cooling technology, each offering unique features and capabilities tailored to meet diverse needs while ensuring efficient and reliable climate control. With their cutting-edge technologies, these systems exemplify the future of home and commercial heating solutions.