Desa REM10PT installation manual Product Identification, Unpacking

Page 3

SAFETY INFORMATION

Continued

Any safety screen or guard removed for servicing the appliance must be replaced prior to operating the heater.

Keep the appliance area clear and free from combus- tible materials, gasoline and other flammable vapors and liquids.

1.Install and use heater with care. Follow all local ordinances and codes. In the absence of local ordinances and codes, refer to the Standard for Storage and Handling of Liquefied Petro- leum Gas, ANSI/NFPA 58 and the Natural Gas Installation Code, CAN/CGA B149.2. This instructs on the safe storage and handling of propane/LP gases.

2.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

3.This heater may be used in a recreational enclosure or temporary construction work enclosure with a remote refillable propane/LP cyl- inder ONLY when the cylinder is located outdoors and the heater is used with the hose kit #LPA3090 (included with this heater). NEVER bring a refillable propane/LP cylinder indoors. A fire or explosion can occur causing property damage, serious injury or death.

4.Use only the hose and factory preset regulator provided with the heater. Use only replacement pressure regulators and hose assemblies specified in this manual. See Accessories, page 18.

5.Inspect the hose before each use of the heater. If it is evident there is excessive abrasion or wear, or the hose is cut, it must be re- placed prior to the heater being put into operation. Use replace- ment hose assembly kit #LPA3090 (see Accessories, page 18).

6.Use only propane gas set up for vapor withdrawal.

7.This heater shall not be installed in a bedroom or bathroom.

8.This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. You must provide a minimum 10 square inches of ventilation air for adequate combustion.

9.If heater shuts off, do not relight until you provide fresh, out- side air. If heater keeps shutting off, have it serviced.

10.Keep all air openings in front and bottom of heater clear and free of debris. This will insure enough air for proper combustion.

11.Do not use heater if any part has been under water. Immedi- ately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

SAFETY INFORMATION

3

PRODUCT IDENTIFICATION

UNPACKING

 

 

 

12.Turn off and let cool before servicing. Only a qualified service person should service and repair heater.

13.Operating heater above elevations of 4,500 feet could cause pilot outage.

14.Turn off propane/LP supply when not in use.

15.Check heater for damage before each use. Do not use a dam- aged heater.

16.Do not alter heater. Keep heater in its original state.

17.Do not use heater if altered.

18.This heater can only be used in a recreational or commercial enclosure with a window or roof vent. This heater is not for outdoor use.

19.Before using the heater provide adequate ventilation. An area of 10 square inches of opening of a window or roof vent is needed for adequate combustion and ventilation air.

PRODUCT IDENTIFICATION

Ignitor

Control Knob

Button

Grill

Guard

Glass

FrontPanel

Panel

Heater

Cabinet

Regulator

Hose

Figure 1 - Vent-Free Propane/LP Gas Heater

UNPACKING

1.Remove heater from carton.

2.Remove all protective packaging applied to heater for shipment.

3.Check heater for any shipping damage. If heater is damaged, promptly return to dealer where you bought heater.

For morevisit www..com

110373-01A

Image 3
Contents OWNER’S Operation Installation Manual REM10PTWhat to do if YOU Smell GAS Safety Information Table of ContentsUnpacking Product IdentificationPROPANE/LP Supply Product FeaturesInstallation Local CodesThermostat Sensing Bulb Installing Heater to WallInstalling Bottom Mounting Screw Connecting to Portable Cylinder GAS SupplyInstallation Items Connecting to Permanent GAS SupplyPermanent GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections for Permanent GAS Supply For Your Safety Read Before LightingPressure Testing Heater Gas Connections Operating HeaterShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationBurner Flame Pattern Inspecting BurnerStorage Pilot Flame PatternCabinet Cleaning MaintenanceCleaning Burner Pilot AIR Inlet ODS/PILOT and BurnerObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at REM10PT Pilot Illustrated Parts BreakdownREM10PT Parts ListService Publications Accessories SpecificationsTechnical Service Service HintsOwners Registration Form Postage Required 110373-01A Warranty Information

REM10PT specifications

Desa REM10PT, an innovative solution for modern farming, embodies the convergence of advanced technology and sustainable agricultural practices. Recognized for its efficiency and effectiveness, REM10PT serves as a pivotal platform designed to enhance productivity while minimizing environmental impact.

One of the standout features of the Desa REM10PT is its advanced monitoring system. This system utilizes IoT (Internet of Things) technology to provide real-time data on soil conditions, weather patterns, and crop health. By carefully tracking these metrics, farmers can make informed decisions that lead to optimized resource utilization. This capability not only boosts yield but also conserves water and fertilizers, which is crucial in regions facing water scarcity.

Another key characteristic of the Desa REM10PT is its integration of precision agriculture techniques. With GPS-enabled machinery, farmers can apply inputs precisely where needed, reducing waste and increasing efficiency. This technology aligns with the best practices of modern agriculture, ensuring that every inch of land is utilized effectively.

The design of Desa REM10PT emphasizes sustainability. Constructed using eco-friendly materials, it aims to reduce the carbon footprint associated with traditional farming equipment. Furthermore, it promotes practices that enhance soil health, such as reduced tillage and cover cropping, enabling a regenerative approach to farming.

In addition to these features, Desa REM10PT boasts user-friendly software that simplifies data analysis. Farmers can access an intuitive dashboard that aggregates data from various sources, helping them to visualize trends and make swift decisions. This platform also allows for remote monitoring, empowering farmers to manage their operations from anywhere at any time.

Finally, a key component of Desa REM10PT is its emphasis on community and education. The platform is not just a tool; it is a portal for sharing knowledge and best practices among farmers. Through workshops and online resources, it fosters a collaborative environment where users can learn from each other, enhancing the overall agricultural ecosystem.

In summary, Desa REM10PT encapsulates the future of agriculture with its holistic approach, merging advanced technology, sustainability, and community engagement. By adopting such innovative solutions, the agricultural sector moves toward more productive and environmentally responsible practices, ensuring a bountiful future for generations to come.