Airstream 18 owner manual Slot Fan HP Heater

Page 9

LTD HEATER INSTALLATION

4.Lift heater and align paired brackets as shown and insert bolts in corresponding slots as in table below. Be sure to place washer provided between tap and bracket. Tighten bolts snug but loose enough to slide heater in and out.

 

Slot

 

Fan HP

Heater

 

Fan

 

 

 

 

5

Middle

 

Middle

7.5

End

 

Middle

10

End

 

Middle

15

End

 

End

20

End

 

End

25

End

 

End

 

 

 

 

5.Align mating bracket pairs so that they are in a straight line. Tighten bolts on fan and heater rigid.

6.Make sure the heater stand off dimension is correct for the fan used. Refer to the table below. Slide the heater to meet the stand off dimension all around. Tighten mating brackets rigid. The heater should now be se- curely fastened to the fan. If not tighten all loose connections.

Fan HP

Stand Off

5

 

5"

7.5

 

7"

10

 

7"

15

7

1/2"

20

8

1/2"

25

8

1/2"

 

 

 

Figure 4: Heater aligned with paired brackets and bolts inserted.

Figure 5: Align mating bracket pairs in a straight line.

IMPORTANT!

Figure 6: Check the heater stand off distance, based on fan horsepower.

9

Image 9
Contents Owners Manual 9OK Table of Contents Warranty Safety Alert Symbol Roof Damage Warning and DisclaimerHeater Operation Safety Alert Decals Propane Vapor Models Fuel ConnectionSlot Fan Inlet Bolt Circle Slot Fan HP Heater Page TANT! Thermostat Must be Installed for Safe Operation Stat Must be Installed for Safe Operation Airstream Surface Mount Humidistat EDS Systems only Surface Mount Humidistat AS a Heater Control LOW Temperature Heater Specifications Btus PER Gauge Pressure PSI Propane Models Approximate Modulating Valve Operation Equilibrium Moisture Table for Rough Rice % WET Basis Equilibrium Moisture Table for Shelled Corn % WET BasisEquilibrium Moisture Table for Soybeans % WET Basis Equilibrium Moisture Table for Sorghum % WET BasisEquilibrium Moisture Table for Wheat Soft % WET Basis Page Key Part Number Description GAS HeaterAxial Propane Vapor & Natural GAS Pipetrain Control BOX Parts Page 1004 E. Illinois St Assumption, IL Phone Fax October