Quadra-Fire 3100 owner manual Clearances to Combustibles UL and ULC

Page 6

CLEARANCES TO COMBUSTIBLES (UL AND ULC)

FLOOR PROTECTION: Floor protector must be noncombustible material or equivalent, extending beneath heater and to the front/ sides/rear as indicated.

NOTE: A 3/8” (10mm) minimum thickness tile or equivalent is recommended, but not required.

Minimum clearances to Combustible Materials (in inches and millimeters) for Quadra-Fire 3100 Standard Stove

 

 

Chimney &

 

 

 

 

 

 

Installation

Clearance

Connector

A

B

C

D

E

F

Residential

Standard

Note 1

14”(356)

26”(661)

18”(457)

12”(305)

18”(457)

10”(254)

Residential/Mobile Home

Reduced

Note 2

12”(305)

26”(661)

16”(406)

10”(254)

18”(457)

8”(203)

Alcove

Standard

Note 2 & 3

12”(305)

26”(661)

N/A

10”(254)

18”(457)

8”(203)

Minimum clearances to Combustible Materials (in inches and millimeters) for Quadra-Fire 3100 with top shield

 

 

 

Chimney &

 

 

 

 

 

 

Installation

Clearance

Connector

A

B

C

D

E

F

Residential

Standard

Note 1

12”(305)

24”(610)

16”(406)

10”(254)

16”(406)

8”(203)

Residential/Mobile Home

Reduced

Note 2

10”(254)

24”(610)

14”(356)

8”(203)

16”(406)

6”(153)

Alcove

Standard

Note 2 & 3

10”(254)

24”(610)

N/A

8”(203)

16”(406)

6”(153)

Minimum clearances to Combustible Materials (in inches and millimeters) for Quadra-Fire 3100 Step Top Stove

 

 

 

Chimney &

 

 

 

 

 

 

Installation

Clearances

Connector

A

B

C

D

E

F

Residential

Standard

Note 1

12”(305)

24”(610)

16”(406)

10”(254)

16”(406)

8”(203)

Residential/Mobile Home

Reduced

Note 2

10”(254)

24”(610)

14”(356)

8”(203)

16”(406)

6”(153)

Alcove

Standard

Note 2 & 3

10”(254)

24”(610)

N/A

8”(203)

16”(406)

6”(153)

Note 1: 6” (152mm) diameter single wall, minimum 24 MSG black or blued steel connector pipe with a listed factory-built type HT chimney suitable for use with solid fuels or a masonry chimney.

Note 2: 6” (152mm) diameter double wall insulated connector pipe with listed factory-built type HT chimney or a masonry chimney. (Mobile home venting system must be equipped with a rain cap and spark arrestor.) For installations with a preexisting class A chimney system, a listed stainless steel chimney liner should be installed, or the existing chimney examined by a chimney sweep for acceptable further use.

Note 3: Alcove specifications: Maximum depth of alcove shall be no more than 48” (1219mm). For additional alcove information and clearances, refer to clearances to combustibles above.

NOTE: Unit is approved for use with listed double wall air-insulated chimney connector or elbows.

When locating your stove consider safety, convenience, traffic flow, and the fact that the stove will need a chimney and chimney connector.

FLOOR PROTECTION: Floor protector must be noncombustible material, extending beneath heater and to the front/sides/rear as indicated.

NOTE: A 3/8” (10mm) minimum thickness tile or equivalent is recommended, but not required.

NFPA 211: Use a noncombustible material with 1” (25mm) ventilated air space to reduce clearances. However, this is not to exceed 50% of Quadra-Fire’s specified clearances.

NOTE: Must follow NFPA 211 spacing and materials to qualify. It is also subject to local jurisdiction.

AVOID FIRE: Maintain the designated clearances to combustibles. Insulation must not touch the chimney. You must maintain the designated air space clearance around the chimney. This space around a chimney is necessary to allow natural heat removal from the area. Insulation in this space will cause a heat buildup, which may ignite wood framing.

Page 6

Image 6
Contents Important Safety Notes NorthAmerica’sBestTable of Contents Safety Label found on back of stove Dimensions Pedestal ModelLEG Model Step TOP Pedestal Model Step TOP LEG ModelClearances to Combustibles UL and ULC Venting System Safety ListingInstallation Materials Needed for Your Safety Chimney SystemsChimney Connector Chimney HEIGHT/DRAFTConnection to a Masonry Chimney Page Page Page Page Page Connection to a Metal Prefabricated Chimney Mobile Home Installation Outside AIR KIT Installation LEG ModelsPedestal Models PEDESTAL/LEG KIT Installation ASH Removal System Installation Pedestal ModelLEG Model ASH Removal System Operating and Cleaning Important Please Read Before Using Stove Burning Process Operating InstructionsBlower Operating Instructions Operating TipsBurning Guidelines Building a Fire Wood Selection and StorageMaintenance Door Handle Assembly Glass ReplacementBaffle Removal and Installation Baffle Removal and Installation Brick PatternInstallation of Optional Blower Blower Switch AdjustmentsSteps for Adjusting the Blower Speed Control TOP Heat Shield Installation Accessories and Service Parts AccessoriesPage Page Lifetime warranty