Quadra-Fire QV36DC-A Installing Trim, Refractory, Logs Ember Material, Installing the Trim

Page 28

Step 10. Installing Trim, Refractory, Logs,

and Ember Material

Installing the Trim

Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace, but MUST NEVER overlap onto the front face. The joints between the finished wall and the fireplace top and sides can only be sealed with a 300° F. (149° C) minimum sealant.

!WARNING: WHEN FINISHING THE FIREPLACE, NEVER OBSTRUCT OR MODIFY THE AIR IN- LET/OUTLET GRILLES IN ANY MANNER.

Install optional marble and brass trim surround kits as desired. Marble, brass, brick, tile, or other non-combustible materials can be used to cover up the gap between the sheet rock and the fireplace.

Do not obstruct or modify the air inlet/outlet grilles. When overlapping on both sides, leave enough space so that the bottom grille can be lowered and the trim door removed.

Refractory Kit Placement (BRICK-292)

Figure 39.

Figure 40.

CAUTION: REFRACTORY IS FRAGILE! CAREFULLY

REMOVE THE REFRACTORY FROM THE PACKAG-

ING.

Remove the logs and log grate from the fireplace. Place the back wall refractory centered against the back of the fireplace on the back refractory ledge (see Figure 38).

Figure 39.

Position the right wall all the way to back wall. Secure in po- sition same as was done for the left wall (see Figure 42).

Figure 38.

When positioning the left wall use care in not knocking the back wall down. Position the left wall all the way back against the back wall. Using the retaining clip and screw included, secure the side wall refractory as shown (see Figures 39 and 40).

Figure 42.

Quadra-FireQV36DC-A2161-900 Rev. C • 6/09

31

Image 28
Contents QV36DC-A Do DiscardnotSafety and Warning Information Table of Contents Installation Codes High Altitude Installations Appliance CertificationElectrical Codes C22.1Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsIntroducing Quadra-Fire Gas Fireplaces Pre-installation PreparationANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the QV36DC-A Fireplace Dimensions, Locations Constructing the Fireplace ChaseLocating the Fireplace Clearance RequirementsFraming the Fireplace 27 7/8DVP90ST Installing the Vent System Identifying Vent ComponentsVent System Approvals Tems or Components MAY be UsedFlue Restrictor Instructions Vertical Venting40’ MAX .4 M Straight Up Vertical VentingDegree Elbows Venting with ONE 1 90 Elbow Venting with One 90 ElbowVenting with TWO Elbows Venting with Three 3 90 Elbows Venting with three 90 elbows+ H1 Shield Above the First 900 Elbow in the Venting System To Install the Heat Shield Install Support Brackets12 Hole and Vent Pipe Vent Termination Alcove Applications Minimum Height from Roof to Lowest Discharge Opening Positioning, Leveling, and Securing the Fireplace Gas Control SystemStanding Pilot Ignition System Standing PilotGas Supply Line Gas Pressure RequirementsOptional Accessories Appliance Requirements Step Wiring the FireplaceWall Switch Finishing Hearth ExtensionsInstalling the Trim Installing Trim, Refractory, Logs Ember MaterialRefractory Kit Placement BRICK-292 Before Lighting the Fireplace Lighting the ApplianceFor Your Safety Read Before Lighting Instructions Do not Connect 110 VAC to the Control ValveFireplace Maintenance After the InstallationClimate Control Symptom Possible Causes Corrective Action Standing Pilot Ignition SystemTroubleshooting Symptom Possible Cause Corrective ActionLimited Lifetime Warranty ÎLimited Lifetime Warranty Contact Information Do not Discard this Manual

QV36DC-A specifications

The Quadra-Fire QV36DC-A is a remarkable addition to the world of home heating, exemplifying innovation and efficiency in gas-burning fireplace inserts. Designed for those who seek both aesthetics and functionality in their living spaces, this model offers an impressive blend of features and technologies that enhance not only warmth but also the overall ambiance of any room.

One of the standout characteristics of the QV36DC-A is its direct vent design. This technology allows for a safe and efficient venting system that draws outside air for combustion, ensuring that indoor air quality is maintained. This feature eliminates the need for a traditional chimney, making it an ideal choice for modern homes or those with limited space. The direct vent capability also contributes to a higher efficiency rating, making it more cost-effective and environmentally friendly.

Another key feature of this model is its large viewing area, which is framed by a sleek and stylish surround. The expansive glass front provides a stunning visual display of the flames, creating a warm and inviting atmosphere. The QV36DC-A also comes with a range of decorative options, including various finish choices and customizable log sets, allowing homeowners to tailor the look of their fireplace to suit their personal style.

The QV36DC-A is equipped with advanced heating technologies, including a powerful heating capacity of up to 30,000 BTUs. This ensures that it can effectively heat larger spaces while maintaining a comfortable environment. The unit features adjustable fan speeds and a variable flame control system, allowing users to manipulate the level of heat and ambiance according to their preferences.

Additionally, the Quadra-Fire QV36DC-A is designed for ease of use and maintenance. The included remote control makes it convenient to adjust settings from a distance, while the self-cleaning glass door reduces the frequency of maintenance chores. The durable construction and high-quality materials ensure longevity, making it a wise investment for homeowners.

With its blend of functionality, efficiency, and beauty, the Quadra-Fire QV36DC-A stands as a premier choice for anyone looking to enhance their living space with the warmth and comfort of a gas fireplace insert. Its thoughtful design and advanced features make it not just a source of heat, but a centerpiece that elevates the overall ambiance of any home.