Quadra-Fire QV36DC-A owner manual Safety and Warning Information

Page 2

SAFETY AND WARNING INFORMATION

!READ and UNDERSTAND all instructions carefully before starting the installation. FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty.

!Prior to the first firing of the fireplace, READ the Using Your Fireplace section of the Owners Guide.

DO NOT USE this appliance if any part has been

!under water. Immediately CALL a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water.

!THIS UNIT IS NOT FOR USE WITH SOLID FUEL. Installation and repair should be PERFORMED by a

!qualified service person. The appliance and venting system should be INSPECTED before initial use and at least annually by a professional service person.

More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is IMPERATIVE that the unit’s control compartment, burners, and circulating air passageways BE KEPT CLEAN to provide for adequate combustion and ventilation air.

!Always KEEP the appliance clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

!NEVER OBSTRUCT the flow of combustion and ventilation air. Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operations.

Due to the high temperature, the appliance should

!be LOCATED out of traffic areas and away from furniture and draperies. Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance.

!Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition. Young children should be CAREFULLY SUPERVISED when they are in the same room as the appliance.

!These units MUST use one of the vent systems described in the Installing the Fireplace section of the Owner’s Manual. NO OTHER vent systems or components MAY BE USED.

!This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance MUST USE a separate vent system. Common vent systems are

PROHIBITED.

!INSPECT the external vent cap on a regular basis to make sure that no debris is interfering with the air flow.

!The glass door assembly MUST be in place and sealed, and the trim door assembly MUST be in place on the fireplace before the unit can be placed into safe operation.

DO NOT OPERATE this appliance with the glass

!door removed, cracked, or broken. Replacement of the glass door should be performed by a licensed or qualified service person. DO NOT strike or slam the glass door.

!The glass door assembly SHALL ONLY be replaced as a complete unit, as supplied by the gas fireplace manufacturer. NO SUBSTITUTE material may be used.

!DO NOT USE abrasive cleaners on the glass door assembly. DO NOT ATTEMPT to clean the glass door when it is hot.

Turn off the gas before servicing this appliance. It

!is recommended that a qualified service technician perform an appliance check-up at the beginning of each heating season.

!Any safety screen or guard removed for servicing must be replaced before operating this appliance.

!DO NOT place furniture or any other combustible household objects within 36 inches of the fireplace front.

2

Quadra-FireQV36DC-A2161-900 Rev. C • 6/09

Image 2
Contents QV36DC-A Do DiscardnotSafety and Warning Information Table of Contents Electrical Codes Installation Codes High Altitude InstallationsAppliance Certification C22.1Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsANY Such Action MAY Possibly Cause a Fire Hazard Pre-installation PreparationIntroducing Quadra-Fire Gas Fireplaces Diagram of the QV36DC-A Locating the Fireplace Fireplace Dimensions, LocationsConstructing the Fireplace Chase Clearance RequirementsFraming the Fireplace 27 7/8DVP90ST Vent System Approvals Installing the Vent SystemIdentifying Vent Components Tems or Components MAY be Used40’ MAX .4 M Flue Restrictor InstructionsVertical Venting Straight Up Vertical VentingDegree Elbows Venting with ONE 1 90 Elbow Venting with One 90 ElbowVenting with TWO Elbows Venting with Three 3 90 Elbows Venting with three 90 elbows+ H1 Shield Above the First 900 Elbow in the Venting System To Install the Heat Shield Install Support Brackets12 Hole and Vent Pipe Vent Termination Alcove Applications Minimum Height from Roof to Lowest Discharge Opening Standing Pilot Ignition System Positioning, Leveling, and Securing the FireplaceGas Control System Standing PilotGas Supply Line Gas Pressure RequirementsWall Switch Step Wiring the FireplaceOptional Accessories Appliance Requirements Finishing Hearth ExtensionsRefractory Kit Placement BRICK-292 Installing Trim, Refractory, Logs Ember MaterialInstalling the Trim Before Lighting the Fireplace Lighting the ApplianceFor Your Safety Read Before Lighting Instructions Do not Connect 110 VAC to the Control ValveClimate Control After the InstallationFireplace Maintenance Symptom Possible Causes Corrective Action Standing Pilot Ignition SystemTroubleshooting Symptom Possible Cause Corrective ActionLimited Lifetime Warranty ÎLimited Lifetime Warranty Contact Information Do not Discard this Manual

QV36DC-A specifications

The Quadra-Fire QV36DC-A is a remarkable addition to the world of home heating, exemplifying innovation and efficiency in gas-burning fireplace inserts. Designed for those who seek both aesthetics and functionality in their living spaces, this model offers an impressive blend of features and technologies that enhance not only warmth but also the overall ambiance of any room.

One of the standout characteristics of the QV36DC-A is its direct vent design. This technology allows for a safe and efficient venting system that draws outside air for combustion, ensuring that indoor air quality is maintained. This feature eliminates the need for a traditional chimney, making it an ideal choice for modern homes or those with limited space. The direct vent capability also contributes to a higher efficiency rating, making it more cost-effective and environmentally friendly.

Another key feature of this model is its large viewing area, which is framed by a sleek and stylish surround. The expansive glass front provides a stunning visual display of the flames, creating a warm and inviting atmosphere. The QV36DC-A also comes with a range of decorative options, including various finish choices and customizable log sets, allowing homeowners to tailor the look of their fireplace to suit their personal style.

The QV36DC-A is equipped with advanced heating technologies, including a powerful heating capacity of up to 30,000 BTUs. This ensures that it can effectively heat larger spaces while maintaining a comfortable environment. The unit features adjustable fan speeds and a variable flame control system, allowing users to manipulate the level of heat and ambiance according to their preferences.

Additionally, the Quadra-Fire QV36DC-A is designed for ease of use and maintenance. The included remote control makes it convenient to adjust settings from a distance, while the self-cleaning glass door reduces the frequency of maintenance chores. The durable construction and high-quality materials ensure longevity, making it a wise investment for homeowners.

With its blend of functionality, efficiency, and beauty, the Quadra-Fire QV36DC-A stands as a premier choice for anyone looking to enhance their living space with the warmth and comfort of a gas fireplace insert. Its thoughtful design and advanced features make it not just a source of heat, but a centerpiece that elevates the overall ambiance of any home.