Sierra Products EF-5001UB owner manual Venting and Installation Clearances

Page 2

Figure 1 -Overall Dimensions

OU TSIDE CO MBU STION AIR IS MAND ATO RY IN MO BILE OR MO DULAR HOM E INSTALLATIONS.

CAU TIO N: D O N OT CO NN ECT T O AN Y AIR DISTRIBUTION DUCT O R SYSTEM .

VENTING AND INSTALLATION

CLEARANCES

CONT ACT LOCAL BUILDING OFFICIALS ABOUT RE- STRICTIONS AND INSTALLATION INSPECTION REQU IREM ENTS IN YOU R AREA.

A LISTED, 4" MINIMU M T YPE "L" PELLET VENT PIPE IS MANDATORY ON ALL INSTALLATIONS.

DO NO T INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT, DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOT HER APPLIANCE.

Use only listed 4" minimum Type "L" pellet vent and components for installation. The exhaust vent system must be attached to the unit and to each adjoining section. All joints for connector pipe shall be fastened with at least three screws. If vented horizontally, joints shall be made gas-tight by sealing with high temperature silicon or

m aterial spec ified by vent pipe manufacturer . Failure to use listed pellet vent pipe or install it per m anufacturers instructions will void your warranty.

INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANU FACTURER

Vent Pipes’ inner and outer diameters may vary. Check with vent pipe m anufacturer for further details.

Figure 2

WARN ING : Installation of a M obile Ho me Attachment Kit P/N 10412 and outside combustion air is mandatory in mobile or modular home installations although it may

also be used in all residential applications.

An outside air inlet MU ST be provided for combustion

and ventilation air. The air inlet must remain unrestricted while unit is in use. Outside air connection is located in the rear of the heater (Figure 2). Use conduit pipe or metal flex pipe and/or fittings to mak e the air intake hook-up.

CAUTION: STRUCTURAL INTEGRITY OF THE MO BILE HOME FLOOR, WALLS AND CEILING/ROOF MUST BE MAINTAINED.

1.W hen deciding on the location of your heater and vent pipe, try to minimize the alteration and reframing of struc tural com ponents of the building . Vent pipe must be installed so that access is provided for inspection and cleaning.

2.Avoid installing heater in high traffic areas. Keep children well away from the heater when in operation.

3.A 3" clearance to combustibles must be maintained for horizontal and vertical venting. W hen passing through ceilings or walls, you must use a listed wall thimble, making sure all combustible materials and insulation products are a minimum of 3" away from the pellet vent pipe.

4.A non-com bustible hearth pad must be used if installed on a carpet, wood floor or other combusti- ble material (see Figure 3).

5.W hen installing the exhaust vent into an existing chimney, a tee must be installed behind the heater before going up into the chim ney. This is necessary in order to remove fly ash accumulation.

6.Exit termination (distance to openings):

a.3 ft. minimum above any forced air inlet located within 10 ft.

b. 4 ft. minimum below and horizontally or 1 ft. minimum above any door, window or gravity air inlet into any building.

2

Image 2
Contents Listed by OMNI-Test Laboratories, Inc Report No -S-01-4 General Information2006 Exit termination distance to openings Venting and Installation ClearancesAn outside air inlet MU ST be provided for combustion Page Wall Thermostat Installation Unit InstallationAutolite Installation Instructions Remote Control Thermostat InstallationSTART-UP and Operation Fuel SelectionAutolite Operation Priming the feed systemFilling the Hopper and Start-Up Feed Trim AdjustmentMatch Light Fire and START-UP Canadian Requirements Disposal of AshesOptional 12V HOOK-UP & Operation Maintenance Procedure TROUBLE-SHOOTING Air box clean out, air damper adjustmentHI TEMP/FLUE and Trim Indicators Customer Service & Replacement PartsItem No Part Number Description

EF-5001UB specifications

The Sierra Products EF-5001UB is a highly efficient, versatile, and user-friendly product that caters to a range of needs, making it an essential addition to any workspace. This multifaceted unit excels in offering an array of features and technologies designed to enhance productivity and user experience.

One of the standout characteristics of the EF-5001UB is its robust design. Built to withstand rigorous use, it combines durability with a sleek aesthetic, making it suitable for both industrial and office environments. The compact size of the unit allows for easy placement, enabling users to maximize their workspace without sacrificing performance.

The EF-5001UB is equipped with advanced energy-efficient technology that not only reduces power consumption but also minimizes the environmental impact. This feature aligns with the growing trend towards sustainable practices, making it an ideal choice for organizations focused on green initiatives. Furthermore, its operational design aids in reducing noise levels, allowing for a quieter working environment.

On the technology front, the EF-5001UB boasts an intuitive interface that simplifies its operation. Users can easily navigate through settings thanks to its user-friendly controls, which include digital displays and programmable options. This ease of use is complemented by superior connectivity features, enabling seamless integration with a variety of devices and networks. Whether connecting via USB or wireless options, users enjoy a hassle-free experience.

The performance specifications of the EF-5001UB are impressive, offering high-speed processing capabilities that enhance its functionality. Its reliable performance ensures that tasks are completed efficiently, making it suitable for both heavy-duty jobs and everyday applications.

Furthermore, the Sierra Products EF-5001UB emphasizes versatility. Its multi-function capabilities allow it to perform various tasks, catering to diverse business needs—from printing and scanning to data storage and retrieval. This adaptability makes it a valuable asset for businesses looking to streamline operations and improve productivity.

In summary, the Sierra Products EF-5001UB combines innovative technologies, efficiency, and durability in a compact and versatile unit. Its user-friendly interface, sustainable design, and multifunctional abilities make it a premier choice for anyone seeking a reliable solution to enhance their workflow. As organizations continue to prioritize performance and sustainability, the EF-5001UB stands out as a forward-thinking product poised to meet the demands of modern workplaces.