Napco Security Technologies XP-400 installation instructions XP-600 Commands

Page 10

WI1370 XP-400 Installation Instructions

Zone LED

Meaning

 

 

OFF

User Arm/Disarm Code not programmed

 

 

Flashing

User Arm/Code is currently being programmed

 

 

Steady

User Arm/Disarm Code has been programmed

 

 

TABLE 4 ZONE LED DEFINITION-USER PROGRAM MODE

While in User Program Mode the W Armed, X READY and HSystem Trouble LEDs will

continue to flash, follow the example below to program a User 2’s code to 1923.

User Mode Programming Example:

1.Press 2, Zone 2 LED will Flash

2.Enter 1923, Zone 2 LED will

continue to flash until the 4th digit is entered. The keypad will beep 4 times confirming a valid entry (Zone LED steady).

Deleting a User Code

Press the number of the User to be deleted, the zone LED will be flashing indicating that the user has been selected. Press the A4, the LED

associated with the user will now be OFF.

Exiting User Program Mode

To exit User Program Mode press the bkey.

XP-600 Commands

User Commands

A1Bell Test

Enter this command to turn on the Bell, keypad sounder and keypad LEDs for 2 seconds. The battery is tested during a Bell Test, and automatically every *24 hours to ensure proper battery operation under load. The Alarm output requires a battery in order to supply the specified output. If the battery cannot sustain the load, a low battery indication will be displayed. A battery test is also performed on power-up after a 3 minute delay.

*A battery test occurs every 4 hours when Household Fire [96-3] has been selected.

CCGroup Bypass

Enter this command to bypass all Exit/Entry Follower Zones or Home/Away Zones (only if the system is programmed exclusively for Home/Away with Delay zones).

A4Instant

Enter this command before or after arming to remove the entry delay on Entry/Exit Zones. The keypad ARMED LED will flicker rapidly. Faulting a Exit/Entry Zone will result in an immediate alarm.

A5Chime ON/OFF

Enter this command to turn chime ON/OFF. The Keypad will chime on any zone that has not been selected as an Exit/Entry Follower Zone, Home/Away with Delay Zones, or 24 Hour Zone.

A 8 + User 1 Code - User Program

Mode

A9Keypad Sleep Mode ON/OFF

Enter this command to turn the keypad sounder ON/OFF. When the keypad is in Sleep mode all keypad sounds will be silenced except for keypad feedback beeps and Keypad Sounder on Alarm.

User Commands - Optional

A0Easy Exit/Easy Arm

If enabled in Dealer programming, enter this command while the panel is Armed to allow 3 minutes to exit the premises through Exit/Entry and Exit/Entry Follower Zones. Enter a0to

arm the panel. To disarm the panel a valid Arm/ Disarm code must be entered. Requires Easy Exit/Easy Arm [21-2] to be enabled.

A3 Access on PGM

If enabled in Dealer programming, enter this command to activate the PGM output (Terminal 15) for 5 seconds.

10

Image 10
Contents Napco WI1370 1/05 XP-400 Features Table of ContentsGeneral Information Specifications Current & Voltage RatingsEuropean E.M.C. Regulations CE Certification Optional AccessoriesListings and Approvals Ordering InformationProgramming the Panel Installation WiringKeypad Operation Panel OperationBypassing User Program Mode XP-600 Commands Zone Features Dealer CommandsWireless Operation Signal Strength 02Exit/Entry Follower Zones 03Auto-Bypass Reentry Zones06Open Circuit Zones Hour ProtectionSystem Features System Times23Programmable Output Features WI1370 XP-400 Installation Instructions 21Keypad Features22Miscellaneous Features 24Programmable Output FeaturesPager Programming 34Zone Report, Telco 35Zone Restore Report, Telco33Receiver Options 36System Reporting, TelcoBackup Telephone Programming Telephone Number 3 Programming Report Codes66Ambush Report Code Enhanced Communicator FeaturesWireless 67Telephone Number81 82 Wireless Keyfobs 90Callback Telephone Number 92Downloading FeaturesDownloading 91Ring CountDealer Programming Viewing System Troubles System TroublesSystem Trouble Reporting System Troubleshooting Keypad LEDs Flicker How do I remove Keypad Sounder on Alarm?Transmitters not responding? No Keypad Entry Sounder during Entry Time?E1XP-400 Wiring Diagram Napco Limited Warranty
Related manuals
Manual 16 pages 52.12 Kb

XP-400 specifications

Napco Security Technologies has established itself as a leading name in the field of security solutions, and one of its standout products is the XP-400, a cutting-edge alarm panel designed for modern security applications.

The Napco XP-400 is recognized for its robust performance and versatility, making it suitable for both residential and commercial security systems. At the heart of its design is an advanced microprocessor that ensures seamless operation and efficient processing of security signals. This intelligent technology allows for faster response times and greater reliability compared to traditional panels.

One of the main features of the XP-400 is its ability to support a wide array of devices. It can accommodate a variety of sensors, keypads, and other peripherals, enabling users to customize their security systems to meet specific needs. The panel supports both hardwired and wireless devices, providing flexibility in installation and enhancing the overall adaptability of the security system.

Security is further enhanced through the XP-400's integration with Napco's proprietary technologies. The panel features built-in alarm verification, which significantly reduces false alarms by allowing for the confirmation of intrusion events before dispatching emergency services. This feature is critical for maintaining a good relationship with local authorities and ensures efficient utilization of resources.

Moreover, the XP-400 utilizes advanced communication technologies, supporting various forms of connectivity, including phone line, cellular, and internet-based connections. This multi-faceted communication strategy ensures that alerts and notifications are promptly delivered to users and monitoring centers, regardless of the circumstances.

In terms of user interface, the XP-400 is designed with ease of use in mind. The panel includes user-friendly keypads that allow for straightforward operation, programming, and user management. The intuitive layout ensures that even those with limited technical knowledge can navigate and manage their security system effectively.

Another notable characteristic of the XP-400 is its scalability. As security needs evolve, the panel can be expanded with additional zones and features, ensuring long-term viability and protection for its users. This scalability not only extends the life of the investment but also allows for future upgrades in response to changing security technologies and threat landscapes.

In conclusion, the Napco Security Technologies XP-400 stands out as a reliable and versatile security solution. With its advanced microprocessor, comprehensive device support, alarm verification, and flexible communication capabilities, it remains an excellent choice for those looking to enhance their security infrastructure. Its user-friendly design and scalability further solidify its reputation as a top-tier security panel on the market.