Napco Security Technologies XP-400 03Auto-Bypass Reentry Zones, 06Open Circuit Zones

Page 12

WI1370 XP-400 Installation Instructions

To eliminate this fixed 20-second entry delay, also program zones as Exit/Entry Follower Zones [02].

To return protection to zones of this type, press cb from the keypad or Mor

N from a Keyfob. Program the Keyfob AUX 1 or AUX 2 button for Full Set [81-7].

NOTE:

Auto Interior Bypassing - Also program zones as Home/Away with Delay Zone(s) [01] to automatically bypass at the expiration of the exit delay if the EXIT/ENTRY Zone(s) are not violated during the exit delay.

[03]Auto-Bypass Reentry Zones

Zones programmed as this zone type are

[06]Open Circuit Zones

Program this zone type if unsupervised normally open circuit devices are required The programming option is not permitted for UL installations.

Normally Open Zone Wiring

If A0 is Entered during Exit Time, Home/

Away with Delay Zones will be automatically bypassed, even if the Exit/Entry Zone is violated. Easy Exit/Easy Arm [22-2] must be enabled.

[02]Exit/Entry Follower Zones

Entry Delay allows the user time to enter and disarm. Allows exit after the panel is armed without setting off an immediate alarm and allows entry only if an Exit/Entry

permitted to be faulted at the time of arming. Once the zone is restored, while the control panel is still armed, the zone will automatically be unbypassed and any subsequent violations of the zone will cause an alarm condition.

[04]24-Hour Protection

Wire the normally open contact

as shown (Zone 4). EZ Zone DoublingTM resistor

is required. Program the zone for

Open Circuit [06].

9.3K (Z)

 

ZONE 4

2

(E)

.2K

 

ZONE 1

Zone [00] has been violated first. Zones of this type have a three (3) minute power-up delay, and do not display or cause an alarm if faulted when the system powers up. Pressing the b key cancels the 3 minute timer.

Group Bypassing - Zones programmed as Exit/Entry Follower Zones will be Group bypassed if the ccis pressed while disarmed or within the Exit Delay.

A zone that provides protection at all times, whether or not the system is armed.

[05]40 ms Loop Response

Normally loop response is 750 ms, select this option to change the loop response to 40 ms. The slower the loop response, the less sensitive the system will be to intermittents (swingers). The programming option is not permitted for UL installations.

FIGURE 5 OPEN CIRCUIT WIRIING

[07]Burg (Steady) Output

Enables the Bell Output on a zone trip for each zone selected. The Bell Output will remain ON for the length of time

programmed for Burg (Steady) Output [07]

or it will remain ON until turned off by entering a valid Arm/Disarm Code; 0 means output will stay ON until reset.

12

Image 12
Contents Napco WI1370 1/05 Table of Contents XP-400 FeaturesGeneral Information Specifications Current & Voltage RatingsOptional Accessories Listings and ApprovalsEuropean E.M.C. Regulations CE Certification Ordering InformationProgramming the Panel Installation WiringKeypad Operation Panel OperationBypassing User Program Mode XP-600 Commands Dealer Commands Zone FeaturesWireless Operation Signal Strength 03Auto-Bypass Reentry Zones 06Open Circuit Zones02Exit/Entry Follower Zones Hour ProtectionSystem Features System TimesWI1370 XP-400 Installation Instructions 21Keypad Features 22Miscellaneous Features23Programmable Output Features 24Programmable Output FeaturesPager Programming 35Zone Restore Report, Telco 33Receiver Options34Zone Report, Telco 36System Reporting, TelcoBackup Telephone Programming Telephone Number 3 Programming Report CodesEnhanced Communicator Features Wireless66Ambush Report Code 67Telephone Number81 82 Wireless Keyfobs 92Downloading Features Downloading90Callback Telephone Number 91Ring CountDealer Programming System Troubles Viewing System TroublesSystem Trouble Reporting System Troubleshooting How do I remove Keypad Sounder on Alarm? Transmitters not responding?Keypad LEDs Flicker No Keypad Entry Sounder during Entry Time?E1XP-400 Wiring Diagram Napco Limited Warranty
Related manuals
Manual 16 pages 52.12 Kb

XP-400 specifications

Napco Security Technologies has established itself as a leading name in the field of security solutions, and one of its standout products is the XP-400, a cutting-edge alarm panel designed for modern security applications.

The Napco XP-400 is recognized for its robust performance and versatility, making it suitable for both residential and commercial security systems. At the heart of its design is an advanced microprocessor that ensures seamless operation and efficient processing of security signals. This intelligent technology allows for faster response times and greater reliability compared to traditional panels.

One of the main features of the XP-400 is its ability to support a wide array of devices. It can accommodate a variety of sensors, keypads, and other peripherals, enabling users to customize their security systems to meet specific needs. The panel supports both hardwired and wireless devices, providing flexibility in installation and enhancing the overall adaptability of the security system.

Security is further enhanced through the XP-400's integration with Napco's proprietary technologies. The panel features built-in alarm verification, which significantly reduces false alarms by allowing for the confirmation of intrusion events before dispatching emergency services. This feature is critical for maintaining a good relationship with local authorities and ensures efficient utilization of resources.

Moreover, the XP-400 utilizes advanced communication technologies, supporting various forms of connectivity, including phone line, cellular, and internet-based connections. This multi-faceted communication strategy ensures that alerts and notifications are promptly delivered to users and monitoring centers, regardless of the circumstances.

In terms of user interface, the XP-400 is designed with ease of use in mind. The panel includes user-friendly keypads that allow for straightforward operation, programming, and user management. The intuitive layout ensures that even those with limited technical knowledge can navigate and manage their security system effectively.

Another notable characteristic of the XP-400 is its scalability. As security needs evolve, the panel can be expanded with additional zones and features, ensuring long-term viability and protection for its users. This scalability not only extends the life of the investment but also allows for future upgrades in response to changing security technologies and threat landscapes.

In conclusion, the Napco Security Technologies XP-400 stands out as a reliable and versatile security solution. With its advanced microprocessor, comprehensive device support, alarm verification, and flexible communication capabilities, it remains an excellent choice for those looking to enhance their security infrastructure. Its user-friendly design and scalability further solidify its reputation as a top-tier security panel on the market.