INDICATOR
LIGHT
Figure 3
INSTALLATION OF FRONT COVER (GRILLE) AND
THERMOSTAT KNOB
1.Position the front cover so the four (4) holes on the side align with the tabs on the plastic pieces of the heat deck.
2.Hook the front cover over the tabs on one side then rotate the front cover into place making sure that all four tabs are snapped onto the front cover.
3.Fit the thermostat knob onto the thermostat shaft and push into place.
HEATER CHECKOUT AND OPERATION
1.After heater is completely assembled, push the disconnect switch to the “on” position and rotate thermostat knob coun- terclockwise until control stops. This is the minimum heat setting.
2.Turn power supply to heater “ON” at main switch panel.
3.Heater should not operate. If it operates, disconnect power and
4.Rotate thermostat clockwise until it stops (maximum heat setting) and wait at least 2 minutes. Fan control will delay fan coming on until element is warm.
5.If heater and fan do not come on, disconnect power and check wiring.
6.Allow heater to continue to operate until room temperature reaches desired comfort level. Then rotate thermostat knob counterclockwise slowly until thermostat clicks off. Fan will continue to operate for a minute or so until element cools.
7.It may be necessary to readjust thermostat a time or so until exact comfort level is attained. Rotation in the clockwise direction will increase the amount of time the heater will pro- duce heat. Rotation in the counterclockwise direction will reduce the amount of time the heater is on.
NOTE: For best results, the heater should be left “ON” constantly during
the heating season as the thermostat, when properly set, will maintain the desired temperature. In the full
remain off until the room temperature drops well below freezing.
Figure 4
MAINTENANCE AND CLEANING
Your heater is designed for years of
Once each year, the heater | should be cleaned to remove dust and other |
|
foreign material which has | collected during the heating season, as foll | ows: |
1.Turn power off at main switch.
2.Remove thermostat knob.
3.Remove front cover by depressing plastic tabs with a flat bladed screwdriver as shown in Figure 4. Release both tabs on one side then rotate cover off of heater assembly.
4.Use vacuum cleaner with brush attachment to remove dust and dirt
that has accumulated in heater (especially around element and fan blade). Do not use water or any cleaners to clean heater compo- nents.
5.Replace grille and thermostat knob.
6.Wipe grille clean with a damp cloth. DO NOT use waxes or any cleaners that leave a residue since these may discolor during heater operation.
7.Turn the main line switch on at the switch panel to restore power to heater. The heater is now ready for another season of operation.
OPERATIONAL NOTICE
Your heater is equipped with an automatic reset high limit control that
will automatically turn the | heater off to prevent a fire if the heater over- |
heats. Should this occur, the indicator light will illuminate and will contin- ue to shine until the limit resets.
!CAUTION
THE ILLUMINATED INDICATOR LIGHT SIGNIFIES THE HEATER
HAS BEEN SUBJECTED TO SOME ABNORMAL CONDITION.
CHECK HEATER TO INSURE THAT IT HAS NOT BEEN BLOCKED IN
ANY MANNER (IF SO, REMOVE BLOCKAGE). IF THERE IS NO
INDICATION OF BLOCKAGE, IT IS RECOMMENDED THE HEATER
BE CHECKED BY A REPUTABLE ELECTRICIAN OR REPAIR SER-
VICE TO INSURE THE HEATER HAS NOT BEEN DAMAGED.
3