![](/images/new-backgrounds/1057219/5721913x1.webp)
8537 Upright Currys cyclone ib 12/05/2003 18:13 Page 7
Removing the floor nozzle cover KL
1Disconnect the cleaner from the mains supply.
2Place the cleaner upside down in the flat position.
3Use a
4Turn the cleaner over and remove the carpet height adjustment knob fi.
5Remove the two screws at the rear and lift the rear of the cover over the handle release button and unclip the cover from the front of the floor nozzle L.
Replacing the belt MN
carpet height adjustment knob back on.
13 Replace the two screws on the top of the floor nozzle cover and the three screws underneath the floor nozzle - do not overtighten.
Safety cut-out
If the cleaner overheats a motor protection thermostat will automatically switch the motor off. If this happens, switch the cleaner off, unplug from the power supply and leave the cleaner to cool for at least 30 minutes. Check the airways for blockages and clean the filters before restarting.
6If the belt has broken, ensure all pieces are removed.
7Lift off the belt cover ˜.
8Grasp the brush bar ¯ at both ends and lift straight up.
9Place one end of the new belt over the metal motor shaft pin and the other around the pulley end of the brush N.
10Align brush end plates with their guide slots and push the brush bar down into place.
11
12
Helpline
If you have any difficulty with your appliance, do not hesitate to call us. We’re more likely able to help than the store from where you bought the product.
Please have the following information ready to enable our staff to deal with your query quickly:
•Name of the product
•Model number as shown on the underside of the appliance.
K
L
fi
˜ M
¯
N
7