HOW TO USE

 

- Before operating the product, connect the power plug to a dedicated

Tips

electric outlet.

- Once the power is turned on, you will see the previously used operation mode,

 

already set for you to use.

To operate the manual mode

Press the power button and then select the speed of the wind by pressing the speed button.

To select the auto mode

Press the power button and then select the auto mode button.

Auto mode

Auto operating mode sets the wind speeds (step 1, 2, or 3) depending on the air pollution states that are detected by the pollution sensor.

When the pollution levels stay in step 1 for approximately 10 minutes, the product switches to power saving mode.

In the power saving mode, the fan is turned off to minimize the power consumption and all displays except the power and auto indicators are turned off.

When the pollution level increases to level 2 or higher, the power saving mode is turned off. When the power saving mode continues for 30 minutes, the product temporarily switches from the power saving mode to step 1 to blend the surrounding air.

 

Pollution level 1

Pollution level 2

Pollution level 3 or higher

Power saving mode

SPEED

Step 1

Step 2

Step 3

Fan off

13

Image 14
Contents Coway Air Purifier AP-1008DH Power saving mode FeaturesPollution level indicator/ mood lamp Mcctm medium filterContents Dear CustomersSafety Information Electricity SafetyOr combustible materials are used or stored Installation SafetyDo not install the product on a sloped floor Operation Safety Outlet Unplug the product before you clean itProduct or using benzene or Thinner Objects stuck in the upper part of the productParts Name Speed indicator Pollution sensor unitPower cord HandleAIR Purified Process Pre-filter Mcctm medium filter Deodorization filterOpen the front cover PreparationsPlease Check Before Use Open the front cover by pulling the upper part of itIndication Part Speed indicatorOperation / Indication Part Light sensorOperation Part CleanBlue Lightly polluted Polluted Highly Light purple Dark purpleTo select the auto mode HOW to USETo operate the manual mode Press the power button and then select the auto mode buttonTo operate the silent mode Sensitive Standard Insensitive Adjust Particle SensorHow to Adjust the Sensitivity of the Pollution Sensor Speed stepCleaning the product body every 2 ~ 4 weeks Cleaning the air inlet and outlet every 2 monthsCleaning the front cover Cleaning Method Cleaning the pre-filter every 2 ~ 4 weeksFilter cleaning and replacement cycles Filter ReplacementHow to replace filters Filter replacement indicatorSwitches to power saving mode, turning TroubleshootingSymptom Check Measures to take Off the fan automaticallySpecification Product specification Air PurifierAP-1008BH/CH/DH Add Woongjin Coway USA, INC Call Center 213 386-9900 / 213 FAX 213001