Procom ML300HGA Parts List ML300TGA, KEY ML300TGA Description QTY, NRV81FI-8, Nut

Page 19

PARTS LIST

ML300TGA

This list contains replaceable parts used in your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts 17 on page of this manual.

 

KEY

ML300TGA

 

 

 

 

NO.

PART NO.

DESCRIPTION

QTY

 

1

MB10002

Cabinet Assembly

1

 

2

MB09001

Lower Front Panel Assembly

1

 

3

MB11002

Reflector Unit

1

 

4

ML089-01

Steel Wind Shield

1

 

5

ML084-01

Middle Panel

1

 

6

MB29001

Grill Guard

 

1

 

7

ML069-02

Self Tapping Screw

12

 

8

SIT545-175

Thermostat

Valve Assembly

1

 

9

845-4.8x60Z

Screws

 

2

 

10

ML111-01

Thermostat

Valve Base/Bracket

1

 

11

ML083-03

Ignitor Assembly

1

 

12

ML073-01

Ignitor Line

 

1

 

13

NRV81FI-8

Pressure Regulator

1

 

14

96-4Z

Washer

 

2

 

15

ML079-01

Self Locking Screw

2

 

16

MB40006

Main Inlet Tube Assembly

1

 

17

MB40022

ODS Line Assembly

1

 

18

MB40023

Burner Inlet

Tube Assembly

1

 

19

NBB30-000B1

Burner

 

1

 

20

ML101-01

Burner Connector

1

 

21

ML091-07

Injector

 

1

 

22

ML103-01

Left Burner

Support Bracket

1

 

23

ML104-01

Right Burner Support Bracket

1

 

24

ND2008x800x9

ODS/pilot Assembly

1

 

24_1

ND0803-8

Thermocouple

1

 

24_2

ND0807-B2

Ignitor Electrode

1

 

25

ML105-01

ODS Upper Deflector

1

 

26

6170-5Z

NUT

 

2

 

27

ML060-01

Mounting Bracket

1

 

 

 

PARTS AVAILABLE NOT SHOWN

 

MB28001 ML070-28 ML071-02 ML072-01 ML065-01

Assembly Hardware

CSA Label

Gas Instruction Decal

Inside Warning Label

Thermostat Sensing Bulb Clip

1

1

1

1

2

1 9

Image 19
Contents NON-THERMOSTAT Thermostat Model L300HGAPropane/LP GAS Propane/LP gas P O R TA N T Read thisCarbon Monoxide Poisoning Fresh air at once! Have heaterProduct Features Unusually Tight Construction Fresh AIR for Combustion and VentilationProducing Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationVentilation AIR Ventilation Air From Outdoors,Locating Heater InstallationInstallation Needs Ventilation AIRMethods For Attaching Mounting Bracket To Wall Installing Thermostat Sensing BulbFor ML300TGA Removing Lower Front Panel Of HeaterImportant Do not InstallationInstalling Bottom Mounting Screws Attaching To Wall Anchor MethodTypical Inlet Pipe Diameters Connecting to GAS SupplyTest Pressures Equal To or Less Than 1/2 Psig 3.5 K Pa Checking GAS ConnectionsTo Turn OFF GAS to Appliance Manual Lighting ProcedureLighting InstructionsShutting Off Burner Only pilot stays lit Operating Your HeaterInspecting Burner Cleaning MaintenanceObserved Problem Possible Cause Remedy TroubleshootingInlet gas pressure is too low Heater produces unwanted odors Burning vapors PRO-COM SpecificationsML300HGA ML300TGA ON/OFF/AUTOML300TGA Illustrated Parts BreakdownNUT Parts List ML300TGAKEY ML300TGA Description QTY NRV81FI-8ML300HGA KEY ML300HGA QTY Description Parts List ML300HGAParts AVAILABLE.NOT Shown

ML300HGA, ML300TGA specifications

The Procom ML300HGA and ML300TGA are advanced communication solutions designed for an array of applications, particularly in sectors requiring robust and reliable wireless connectivity. Both models are designed to enhance operational efficiency through enhanced performance and pertinent features.

The ML300HGA model is tailored for high-gain applications, providing exceptional signal strength in demanding environments. This makes it an ideal choice for remote monitoring, industrial communication, and public safety operations where optimal signal reception is critical. It supports multiple frequency bands, including VHF and UHF, allowing flexibility in deployment across various networks.

Equipped with advanced antenna technology, the ML300HGA is designed to minimize noise and interference, ensuring clear communication even in congested frequencies. The rugged construction of this model makes it resilient to harsh environmental conditions—be it extreme temperatures, moisture, or physical impacts, thus increasing its longevity and reliability in the field.

On the other hand, the ML300TGA is designed for versatility and is particularly favored for its compact design and lightweight structure. This model is optimized for applications that require portability without compromising on performance. It is ideal for temporary installations or scenarios where mobility and adaptability are paramount.

Key features of the ML300TGA include multiple input and output options, allowing easy integration with various communication systems. Its modular design allows for easy upgrades and expansions, which is beneficial as organizational needs evolve.

Both models incorporate the latest advancements in antenna design technology, such as low Vswr (voltage standing wave ratio) and high efficiency, which translates to better bandwidth utilization. They also feature weather-resistant capabilities, ensuring functionality in diverse environments while maintaining signal integrity.

Moreover, these devices are designed with user-friendly interfaces, ensuring ease of operation, maintenance, and troubleshooting. The proprietary algorithms deployed in the ML300 series enhance signal processing capabilities, allowing for the management of multiple connections while optimizing performance.

When considering wireless communication equipment, the Procom ML300HGA and ML300TGA provide premier options that combine cutting-edge technology with practical features, addressing the needs of professionals in various fields. From industrial applications to public safety, these models are engineered to deliver dependable, high-quality performance in every situation.