Marking Screw Locations
1. Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.
WARNING: Maintain minimum clearances shown in Figure 8. If you can, provide greater clearances from floor and joining wall.
Mounting Bracket
FASTENING HEATER TO WALL
Attaching to Wall Anchor: This method allows you to attach The mounting bracket is located on mounting bracket to hollow walls
back panel of heater(see figure 6). It has (wall areas between studs) or to been taped there for shipping. Remove solid walls (concrete or masonry).
mounting bracket from back panel. Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.
INSTALLATION

WARNING: Maintain the minimum clearances shown i n F i g u r e 4 . I f y o u c a n , provide greater clearances from floor, ceiling, and joining wall.

Figur 4 -Mounting Clearances As Viewed From Front Of Heater

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Fresh Air for Combustion and Ventilation, page s 4 and 5.

INSTALLING THERMOSTAT SENSING BULB

For ML300TGA

1.Pull out the sensing bulb from the two clips located in the shippng position according to the direction as shown by the arrow. There is no need to take out the two bulb clips.

2.Take out the bulb clip from the hardware package and insert it into the square hole and then insert the sensing bulb into the bulb clip (see Figure 5).

Figure 5 - Moving Thermostat Sensing Bulb

Figure 6 -Mounting Bracket Location

Removing Lower Front Panel Of Heater

1.Remove two screws near bottom corners of lower front panel

2.Pull bottom of lower front panel forward, then down (see Figure 7).

Figure 7 - Removing Lower Front Panel Of Heater

Methods For Attaching Mounting Bracket To Wall

Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart from their centers.Attach mounting bracket to wall only in one of two ways:

1.Attaching to wall stud

2.Attaching to wall anchor Attaching to Wall Stud: This method

provides

the

strongest

hold. Insert

mounting

screws through mounting

bracket and

into wall

studs.

2. Mark screw locations on wall (see Figure 8).

Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only.

3.Remove tape and mounting bracket from wall.

Model ML300TGA, ML300HGA

Figure 8 - Mounting Bracket Clearances

7

Image 7
Contents NON-THERMOSTAT Thermostat Model L300HGAPropane/LP GAS Propane/LP gas P O R TA N T Read thisCarbon Monoxide Poisoning Fresh air at once! Have heaterProduct Features Unusually Tight Construction Fresh AIR for Combustion and VentilationProducing Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationVentilation AIR Ventilation Air From Outdoors,Locating Heater InstallationInstallation Needs Ventilation AIRMethods For Attaching Mounting Bracket To Wall Installing Thermostat Sensing BulbFor ML300TGA Removing Lower Front Panel Of HeaterImportant Do not InstallationInstalling Bottom Mounting Screws Attaching To Wall Anchor MethodTypical Inlet Pipe Diameters Connecting to GAS SupplyTest Pressures Equal To or Less Than 1/2 Psig 3.5 K Pa Checking GAS ConnectionsTo Turn OFF GAS to Appliance Manual Lighting ProcedureLighting InstructionsShutting Off Burner Only pilot stays lit Operating Your HeaterInspecting Burner Cleaning MaintenanceObserved Problem Possible Cause Remedy TroubleshootingInlet gas pressure is too low Heater produces unwanted odors Burning vapors PRO-COM SpecificationsML300HGA ML300TGA ON/OFF/AUTOML300TGA Illustrated Parts BreakdownNUT Parts List ML300TGAKEY ML300TGA Description QTY NRV81FI-8ML300HGA KEY ML300HGA QTY Description Parts List ML300HGAParts AVAILABLE.NOT Shown

ML300HGA, ML300TGA specifications

The Procom ML300HGA and ML300TGA are advanced communication solutions designed for an array of applications, particularly in sectors requiring robust and reliable wireless connectivity. Both models are designed to enhance operational efficiency through enhanced performance and pertinent features.

The ML300HGA model is tailored for high-gain applications, providing exceptional signal strength in demanding environments. This makes it an ideal choice for remote monitoring, industrial communication, and public safety operations where optimal signal reception is critical. It supports multiple frequency bands, including VHF and UHF, allowing flexibility in deployment across various networks.

Equipped with advanced antenna technology, the ML300HGA is designed to minimize noise and interference, ensuring clear communication even in congested frequencies. The rugged construction of this model makes it resilient to harsh environmental conditions—be it extreme temperatures, moisture, or physical impacts, thus increasing its longevity and reliability in the field.

On the other hand, the ML300TGA is designed for versatility and is particularly favored for its compact design and lightweight structure. This model is optimized for applications that require portability without compromising on performance. It is ideal for temporary installations or scenarios where mobility and adaptability are paramount.

Key features of the ML300TGA include multiple input and output options, allowing easy integration with various communication systems. Its modular design allows for easy upgrades and expansions, which is beneficial as organizational needs evolve.

Both models incorporate the latest advancements in antenna design technology, such as low Vswr (voltage standing wave ratio) and high efficiency, which translates to better bandwidth utilization. They also feature weather-resistant capabilities, ensuring functionality in diverse environments while maintaining signal integrity.

Moreover, these devices are designed with user-friendly interfaces, ensuring ease of operation, maintenance, and troubleshooting. The proprietary algorithms deployed in the ML300 series enhance signal processing capabilities, allowing for the management of multiple connections while optimizing performance.

When considering wireless communication equipment, the Procom ML300HGA and ML300TGA provide premier options that combine cutting-edge technology with practical features, addressing the needs of professionals in various fields. From industrial applications to public safety, these models are engineered to deliver dependable, high-quality performance in every situation.