Procom ML300HGA, ML300TGA Installation, Attaching To Wall Anchor Method, Important Do not

Page 8

Attaching Mounting Bracket To Wall

Note: Wall anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater.

Attaching To Wall Stud Method

For attaching mounting bracket to wall studs

1.Drill holes at marked locations using 9/64" drill bit.

2.Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.

3.Insert mounting screws through bracket and into wall studs.

4.Tighten screws until mounting bracket is firmly fastened to wall studs.

Attaching To Wall Anchor Method

For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry)

1.Drill holes at marked locations using 5/16" drill bit. For solid

walls (concrete or masonry), drill at least 1" deep.

2.Fold wall anchor as shown in Figure 9 below.

Figure 9 - Folding Anchor

3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

4.For thin walls (1/2" or less), insert red key into wall

anchor. Push red key to "pop" open anchor wings

(see Figure 10).

INSTALLATION

IMPORTANT: Do not

hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

Figure 10 - Popping Open Anchor Wing For Thin Walls

5.Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors.

6.Insert mounting screws through bracket and into wall anchors.

7.Tighten screws until mounting bracket is firmly fastened to wall.

Placing Heater On Mounting

Bracket

1.Locate two horizontal slots on back panel of heater (see Figure 11).

2.Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.

Figure 11 - Mounting Heater Onto Mounting Bracket

Installing Bottom Mounting Screws

1.Locate two bottom mounting holes. These holes are near bottom on back panel of heater(see Figure 12).

Figure 12 - Installing Bottom Mounting Screws

2.Mark screw locations on wall.

3.Remove heater from mounting bracket.

4.If installing bottom mounting screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under Attaching To Wall Anchor Method. If installing bottom mounting screw

into wall stud, drill holes at marked locations using 9/64"

drill bit.

5.Replace heater onto mounting bracket.

6.Place spacers between bottom mounting holes and wall anchor or drilled hole.

7. Hold spacer in place with

one

hand. With other hand, insert

mounting screw through

bottom

mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole.

8.Tighten both screws until heater is firmly secured to wall. Do not over tighten.

Note: Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 9,10).

8

Image 8
Contents L300HGA NON-THERMOSTAT Thermostat ModelP O R TA N T Read this Carbon Monoxide PoisoningFresh air at once! Have heater Propane/LP GAS Propane/LP gasProduct Features Fresh AIR for Combustion and Ventilation Producing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation Air From Outdoors, Ventilation AIRInstallation Installation NeedsVentilation AIR Locating HeaterInstalling Thermostat Sensing Bulb For ML300TGARemoving Lower Front Panel Of Heater Methods For Attaching Mounting Bracket To WallInstallation Installing Bottom Mounting ScrewsAttaching To Wall Anchor Method Important Do notConnecting to GAS Supply Typical Inlet Pipe DiametersChecking GAS Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 K PaManual Lighting Procedure LightingInstructions To Turn OFF GAS to ApplianceOperating Your Heater Shutting Off Burner Only pilot stays litCleaning Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyInlet gas pressure is too low Heater produces unwanted odors Burning vapors Specifications ML300HGA ML300TGAON/OFF/AUTO PRO-COMIllustrated Parts Breakdown ML300TGAParts List ML300TGA KEY ML300TGA Description QTYNRV81FI-8 NUTML300HGA Parts AVAILABLE.NOT Shown Parts List ML300HGAKEY ML300HGA QTY Description

ML300HGA, ML300TGA specifications

The Procom ML300HGA and ML300TGA are advanced communication solutions designed for an array of applications, particularly in sectors requiring robust and reliable wireless connectivity. Both models are designed to enhance operational efficiency through enhanced performance and pertinent features.

The ML300HGA model is tailored for high-gain applications, providing exceptional signal strength in demanding environments. This makes it an ideal choice for remote monitoring, industrial communication, and public safety operations where optimal signal reception is critical. It supports multiple frequency bands, including VHF and UHF, allowing flexibility in deployment across various networks.

Equipped with advanced antenna technology, the ML300HGA is designed to minimize noise and interference, ensuring clear communication even in congested frequencies. The rugged construction of this model makes it resilient to harsh environmental conditions—be it extreme temperatures, moisture, or physical impacts, thus increasing its longevity and reliability in the field.

On the other hand, the ML300TGA is designed for versatility and is particularly favored for its compact design and lightweight structure. This model is optimized for applications that require portability without compromising on performance. It is ideal for temporary installations or scenarios where mobility and adaptability are paramount.

Key features of the ML300TGA include multiple input and output options, allowing easy integration with various communication systems. Its modular design allows for easy upgrades and expansions, which is beneficial as organizational needs evolve.

Both models incorporate the latest advancements in antenna design technology, such as low Vswr (voltage standing wave ratio) and high efficiency, which translates to better bandwidth utilization. They also feature weather-resistant capabilities, ensuring functionality in diverse environments while maintaining signal integrity.

Moreover, these devices are designed with user-friendly interfaces, ensuring ease of operation, maintenance, and troubleshooting. The proprietary algorithms deployed in the ML300 series enhance signal processing capabilities, allowing for the management of multiple connections while optimizing performance.

When considering wireless communication equipment, the Procom ML300HGA and ML300TGA provide premier options that combine cutting-edge technology with practical features, addressing the needs of professionals in various fields. From industrial applications to public safety, these models are engineered to deliver dependable, high-quality performance in every situation.