Procom QL300RYLA-W, QN300RYLA-W installation manual P O R Ta N T

Page 3

SAFETY INFORMATION WARNINGS

I M P O R TA N T:

R e a d

t h i s

owner’s manual

carefully

and

completely before trying

to

assemble, operate, or

service

this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease, anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP Gas: Propane/LP gas

is odorless. An odor-making agent is added to Propane/LP gas. The

o d o r h e l p s

y o u d e t e c t a

Propane/LP

gas

leak. However,

the odor added to

Propane/LP gas

can fade. Propane/LP gas may be present even though no odor exists.

Natural Gas: Natural gas is odorless. An odor­making agent is added to natural gas. The odor helps you detect a natural gas leak. However, the odor added to natural gas can fade. Natural gas may be present e v e n t h o u g h n o o d o r e x i s t s . M a k e c e r t a i n y o u r e a d a n d understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this fireplace or its controls can be dangerous.

 

 

 

 

 

 

 

1.

This appliance

is only

for

use

 

 

WARNING: Do not allow fans to

 

 

 

 

 

with

the

type

of

gas indicated

 

blow directly into the heater. Avoid any

 

 

 

 

 

on the

rating

plate. This

 

 

drafts

that alter burner flame patterns.

 

 

 

 

 

 

appliance

is

not

convertible

for

 

Ceiling fans can create drafts that

 

 

 

 

 

use

with

other gases.

 

 

 

alter burner flame patterns. Altered

 

 

 

 

 

 

2.

Do

not place

Propane/LP

 

 

burner patterns can cause sooting.

 

 

 

 

 

supply

tank(s)

inside any

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

structure. Locate

Propane/LP

 

 

WARNING: Do not use a blower

 

 

 

 

 

 

supply

tank(s)

outdoors.

 

 

insert, heat exchanger insert, or other

 

3.

If you

smell

gas

 

 

 

accessory

not approved for use with

 

￿

Shut

off gas

supply.

 

 

 

this heater.

 

 

￿

Do not try to light

any appliance.

 

 

 

 

 

 

 

￿ Do not

touch

any

electrical switch:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

do not use any phone in your

 

 

Due

to

high

temperatures, the

 

 

 

 

 

 

building.

 

 

 

 

 

 

 

appliance should be located out of

 

 

 

 

 

 

 

 

 

 

￿

Immediately call

your gas

supplier

 

traffic and away from furniture

 

 

from a neighbor’s phone. Follow

 

and draperies.

 

 

 

 

 

 

 

the

gas supplier’s

instructions.

 

 

 

 

 

 

 

 

￿

If you cannot reach your

gas

 

 

Do not place clothing or other

 

 

supplier, call the fire department.

 

flammable material on or near the

4.

 

This heater shall not be installed

 

appliance. Never place any objects

 

 

in a bedroom or bathroom.

 

 

in

the fireplace.

 

 

 

 

5.

Do not use this heater as

a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

wood-burning heater. Use only

 

Heater becomes very hot when

 

 

the logs provided

with the heater.

 

running fireplace. Keep children and

6.

 

Do not add extra logs or ornaments

 

adults away from hot surfaces to

 

 

such as pine cones, vermiculite, or

 

avoid burns or clothing ignition.

 

rock wool.Using these added items

 

 

can cause sooting. Do not add lava

 

Fireplace will

remain hot for a

 

 

 

rock around base. Rock and debris

 

time after shutoff. Allow surfaces

 

 

 

could fall into the control area of

 

to

cool before touching.

 

 

 

heater. After servicing, always

 

 

 

 

 

 

 

 

 

 

 

 

 

 

replace screen before operating

 

Carefully supervise young children

 

heater.

 

 

 

 

 

 

 

 

when they are in the room with the

7.

You must operate

this heater with

 

fireplace.

 

 

 

the heater screen in place. Make

 

 

 

 

 

 

 

sure heater screen is

in

place

 

 

 

 

 

 

 

 

You must operate this heater with

 

before running heater.

 

 

 

the heater screen in place. Make

8.

 

This heater is designed to be

 

sure the heater

screen is in place

 

smokeless. If logs ever appear to

 

before running heater.

 

smoke, turn heater off and call a

 

 

qualified service person. Note:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

During

initial

operation, slight

 

Keep the appliance area clear and

 

smoking could occur due to log

 

free from combustible materials,

 

c u r i n g

a n d

 

h e a t e r

b u r n i n g

 

gasoline, and

other flammable

 

manufacturing residues.

 

 

 

9.

 

To prevent the creation of soot,

 

vapors and liquids.

 

follow the instructions in Cleaning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and Maintenance

 

 

 

3

Image 3
Contents OWNER’S Operation and Installation Manual Table of Contents P O R TA N T Unpacking Safety Information Local CodesProduct Features Safety PilotDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors Ventilation Air From lnside BuildingCheck GAS Type InstallationMinimum Wall and Ceiling Clearances Connecting to GAS SupplyTest Pressures In Excess Of 1/2 PSIG3.5kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 PSIG3.5 kPa InstallingOperating Instrutionof REMOTE-CONTROLLEDBUNER For Your Safety Read Before LightingOperating Heater To Turn OFF GAS to Appliance Shut off heaterOperations TURN-OFF Operations Remote TransmitterOperations Burner Operations TimingCleaning Maintenance Operations KEY-PRESS LockingOperations FAN Main Burner Replacementparts NoteParts Under Warranty CabinetEquipment Shutoff Valve AccessoriesParts not Under Warranty QL300RYLA QN300RYLAObserved Problem PossiblecauseRemedy Cleaning and Maintenance, Page Parts List QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W Page Parts List QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W Placing Instruction Series LOG SET Installation Instructions Installation Instructions for LOG Sets

QN300RYLA-W, QN300RYLA, QL300RYLA, QL300RYLA-W specifications

The Procom QN300RYLA-W, QN300RYLA, QL300RYLA-W, and QL300RYLA are advanced antenna solutions designed for diverse communication needs. These models exemplify cutting-edge technology and innovative design, catering to clients in various sectors, from telecommunications to public safety.

One of the standout features of the Procom antennas is their robust frequency range. The QN300RYLA-W and QN300RYLA models typically support a frequency range of 300 to 470 MHz, while the QL300RYLA-W and QL300RYLA operate in the same bandwidth, providing flexibility for various applications. This capability ensures compatibility with a broad array of devices, enhancing communication reliability.

Procom’s design philosophy emphasizes durability and performance. The antennas are constructed with high-quality materials that can withstand a wide range of environmental conditions. With their weather-resistant properties, these antennas can be deployed in challenging regions, ensuring continuous operation in rain or shine.

The gain characteristics of the antennas are optimized for long-range communication. With gains typically reaching up to 6 dBi, they provide enhanced signal strength and coverage, crucial for critical communications. This is particularly beneficial in urban environments where signal degradation often occurs due to physical obstructions.

Another significant aspect of the Procom QN and QL series is their installation versatility. They can be mounted in different configurations, including vertical or horizontal setup, adapting to specific user requirements and site conditions. This flexibility allows for streamlined deployment in various settings, including rooftops, towers, and vehicles.

These antennas also integrate advanced radiation patterns, which help minimize interference and improve overall performance. This ensures reliable transmission over considerable distances, making them ideal for applications in emergency services, transportation logistics, and industrial communications.

In summary, the Procom QN300RYLA-W, QN300RYLA, QL300RYLA-W, and QL300RYLA antennas deliver exceptional performance, robust design, and versatility for a myriad of communication scenarios. With their advanced technology and user-centric features, these antennas are well-suited to meet the evolving demands of modern communication needs.